Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Nov 17;1(1):13.
doi: 10.1186/1757-1146-1-13.

Effect of foot orthoses on lower extremity kinetics during running: a systematic literature review

Affiliations

Effect of foot orthoses on lower extremity kinetics during running: a systematic literature review

Andrew McMillan et al. J Foot Ankle Res. .

Abstract

Background: Throughout the period of one year, approximately 50% of recreational runners will sustain an injury that disrupts their training regimen. Foot orthoses have been shown to be clinically effective in the prevention and treatment of several running-related conditions, yet the physical effect of this intervention during running remains poorly understood. The aim of this literature review was therefore to evaluate the effect of foot orthoses on lower extremity forces and pressure (kinetics) during running.

Methods: A systematic search of electronic databases including Medline (1966-present), CINAHL, SportDiscus, and The Cochrane Library occurred on 7 May 2008. Eligible articles were selected according to pre-determined criteria. Methodological quality was evaluated by use of the Quality Index as described by Downs & Black, followed by critical analysis according to outcome variables.

Results: The most widely reported kinetic outcomes were loading rate and impact force, however the effect of foot orthoses on these variables remains unclear. In contrast, current evidence suggests that a reduction in the rearfoot inversion moment is the most consistent kinetic effect of foot orthoses during running.

Conclusion: The findings of this review demonstrate systematic effects that may inform the direction of future research, as further evidence is required to define the mechanism of action of foot orthoses during running. Continuation of research in this field will enable targeting of design parameters towards biomechanical variables that are supported by evidence, and may lead to advancements in clinical efficacy.

PubMed Disclaimer

References

    1. Fredericson M, Anuruddh M. Epidemiology and Aetiology of Marathon Running Injuries. Sports Medicine. 2007;37:437–439. doi: 10.2165/00007256-200737040-00043. - DOI - PubMed
    1. McKean K, Manson N, Stanish W. Musculoskeletal Injury in the Masters Runners. Clinical Journal of Sport and Medicine. 2006;16:149–154. doi: 10.1097/00042752-200603000-00011. - DOI - PubMed
    1. van Middelkoop M, Kolkman J, van Ochten J, Bierma-Zeinstra S, Koes B. Course and Predicting Factors of Lower-Extremity Injuries After Running a Marathon. Clinical Journal of Sport and Medicine. 2007;17:25–30. doi: 10.1097/JSM.0b013e3180305e4d. - DOI - PubMed
    1. van Gent R, van Middelkoop M, van Os A, Bierma-Zeinstra S, Koes B. Incidence and Determinants of Lower Extremity Running Injuries in Long Distance Runners: A Systematic Review. British Journal of Sports Medicine. 2007;41:469–480. doi: 10.1136/bjsm.2006.033548. - DOI - PMC - PubMed
    1. Hootman J, Macera C, Ainsworth B, Martin M, Addy C, Blair S. Predictors of Lower Extremity Injury Among Recreationally Active Adults. Clinical Journal of Sport and Medicine. 2002;12:99–106. doi: 10.1097/00042752-200203000-00006. - DOI - PubMed