Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Apr;135(4):1010-1018.
doi: 10.1378/chest.08-2048. Epub 2008 Nov 18.

Comparative performance of tuberculin skin test, QuantiFERON-TB-Gold In Tube assay, and T-Spot.TB test in contact investigations for tuberculosis

Affiliations
Comparative Study

Comparative performance of tuberculin skin test, QuantiFERON-TB-Gold In Tube assay, and T-Spot.TB test in contact investigations for tuberculosis

Roland Diel et al. Chest. 2009 Apr.

Abstract

Rationale: Mycobacterium tuberculosis (MTB)-specific interferon-gamma release assays (IGRAs) are an alternative or adjunct to the tuberculin skin test (TST) in identifying recent contacts with latent tuberculosis infection (LTBI), but there are scarce data directly comparing performance of the tests.

Objective: To evaluate the agreement between both IGRAs and to determine which contacts were most likely to represent LTBI, the QuantiFERON-TB-Gold In Tube assay (QFT) and the T-Spot.TB test (T-Spot) were compared in TST-positive persons recently exposed to pulmonary tuberculosis cases.

Methods: Prospectively enrolled close contacts (n = 812) of 123 culture-confirmed tuberculosis source cases underwent IGRA testing using standardized collected data. Factors independently influencing the risk of MTB infection and their interactions with each other were evaluated by multivariate analysis.

Results: Five variables were found to significantly predict a positive IGRA test result (age, source case acid-fast bacilli positive and/or coughing, cumulative exposure time, foreign origin). There was excellent agreement between the two IGRAs (93.9%, kappa = 0.85), with QFT finding 30.2% of contacts positive and T-Spot finding 28.7%. Assuming positivity to both IGRAs as true infection, sensitivity of the TST at > 10 mm was 72% and at > 15 mm was 39.7%. The use of either IGRA as a replacement for the TST would decrease the number of LTBI suspects to be investigated by approximately 70%.

Conclusions: IGRAs are a more accurate indicator of the presence of LTBI than the TST. Both QFT and T-Spot appear to be valuable public health tools, showing excellent agreement with each other.

PubMed Disclaimer

Publication types