Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Mar;30(5):608-17.
doi: 10.1093/eurheartj/ehn511. Epub 2008 Nov 19.

Assessment of subendocardial vs. subepicardial left ventricular rotation and twist using two-dimensional speckle tracking echocardiography: comparison with tagged cardiac magnetic resonance

Affiliations
Comparative Study

Assessment of subendocardial vs. subepicardial left ventricular rotation and twist using two-dimensional speckle tracking echocardiography: comparison with tagged cardiac magnetic resonance

Céline Goffinet et al. Eur Heart J. 2009 Mar.

Abstract

Aims: The aim of this article is to evaluate the accuracy and reproducibility of two-dimensional speckle tracking echocardiography (2D-STE) for the estimation of left ventricular (LV) twist, using tagged cardiac magnetic resonance (cMR) as the reference standard, and to assess how much 2D-STE rotational parameters are affected by the level at which measurements are made within the LV.

Methods and results: Forty-three patients with various heart diseases and 10 healthy volunteers underwent cMR and 2D-STE on the same day. With both methods, basal and apical time-rotation curves were generated at endocardial, midwall, and epicardial levels. By using the most apical cMR short-axis cross-section as a comparator, apical rotation was significantly underestimated by 2D-STE. When 2D-STE and cMR short-axis cross-sections were matched for their internal dimensions, measurements of endocardial, midwall, and epicardial twists no longer differ between cMR and 2D-STE (12.6 +/- 5.9 vs. 12.5 +/- 5.7 degrees , 10.5 +/- 4.6 vs. 9.7 +/- 4.1 degrees , and 8.9 +/- 4.0 vs. 8.4 +/- 3.7 degrees , respectively, all P = ns).

Conclusion: Compared with tagged cMR, 2D-STE underestimates apical rotation and LV twist. This is related to the inability of 2D-STE to image the real LV apex in most of the patients. However, when 2D-STE and cMR data are compared at similar acquisition levels, both techniques provide similar values.

PubMed Disclaimer

Publication types

LinkOut - more resources