Patient dosimetry for total body irradiation using single-use MOSFET detectors
- PMID: 19020482
- PMCID: PMC5722362
- DOI: 10.1120/jacmp.v9i4.2787
Patient dosimetry for total body irradiation using single-use MOSFET detectors
Abstract
We studied the usefulness of a new type of solid-state detector, the OneDose single-use MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements for total body irradiation (TBI). The factory calibration factors supplied by the manufacturer are applicable to conventional radiotherapy beam arrangements and therefore may not be expected to be valid for TBI dosimetry because of the large field sizes and extended source-to-axis distances used. OneDose detectors were placed under a 1-cm thick bolus at the head, neck, and umbilicus of 9 patients undergoing TBI procedures. Thermoluminescent dosimeters (TLDs) were placed beside the detectors. We found that the OneDose readings differed from the TLD readings by 4.6% at the head, 1.7% at the neck, and 3.9% at the umbilicus, with corresponding standard deviations of 3.9%, 2.2%, and 2.7%. For all patient measurements, 95% of the OneDose readings fell within 3.3% +/- 6.0% of the TLD readings. Anthropomorphic phantom measurements showed differences of -0.1% at the neck and -1.2% midway between the phantom's carina and umbilicus. Our results suggest that these detectors could be used for TBI quality assurance monitoring, although TLDs should remain the standard when critical dose measurements are performed. If OneDose detectors are to be used for TBI, the use of more than one at each location is strongly recommended. Because the detectors are designed for single use, they cannot be individually calibrated. However, to obtain institution-specific correction factors for better applicability to TBI dosimetry, measurements of several detectors taken from a particular lot could also be obtained in phantom with the TBI geometry configurations used for patient treatment.
Figures



Similar articles
-
Clinical application of the OneDose Patient Dosimetry System for total body irradiation.Phys Med Biol. 2005 Dec 21;50(24):5909-19. doi: 10.1088/0031-9155/50/24/010. Epub 2005 Dec 6. Phys Med Biol. 2005. PMID: 16333163
-
Calibration of a mosfet detection system for 6-MV in vivo dosimetry.Int J Radiat Oncol Biol Phys. 1998 Mar 1;40(4):987-93. doi: 10.1016/s0360-3016(97)00894-8. Int J Radiat Oncol Biol Phys. 1998. PMID: 9531385
-
Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.J Appl Clin Med Phys. 2015 Jul 8;16(4):266–278. doi: 10.1120/jacmp.v16i4.5433. J Appl Clin Med Phys. 2015. PMID: 26219008 Free PMC article.
-
Total body irradiation, toward optimal individual delivery: dose evaluation with metal oxide field effect transistors, thermoluminescence detectors, and a treatment planning system.Int J Radiat Oncol Biol Phys. 2007 Nov 15;69(4):1297-304. doi: 10.1016/j.ijrobp.2007.07.2334. Epub 2007 Sep 19. Int J Radiat Oncol Biol Phys. 2007. PMID: 17881143
-
Recent developments in phosphate materials for their thermoluminescence dosimeter (TLD) applications.Luminescence. 2021 Dec;36(8):1808-1817. doi: 10.1002/bio.3960. Epub 2020 Dec 21. Luminescence. 2021. PMID: 33047494 Review.
Cited by
-
Is the in vivo dosimetry with the OneDosePlusTM system able to detect intra-fraction motion? A retrospective analysis of in vivo data from breast and prostate patients.Radiat Oncol. 2012 Jun 20;7:97. doi: 10.1186/1748-717X-7-97. Radiat Oncol. 2012. PMID: 22716260 Free PMC article.
-
Build-up material requirements in clinical dosimetry during total body irradiation treatments.J Med Phys. 2016 Apr-Jun;41(2):149-52. doi: 10.4103/0971-6203.181632. J Med Phys. 2016. PMID: 27217628 Free PMC article.
-
Characteristics of mobile MOSFET dosimetry system for megavoltage photon beams.J Med Phys. 2014 Jul;39(3):142-9. doi: 10.4103/0971-6203.139002. J Med Phys. 2014. PMID: 25190992 Free PMC article.
-
Small field electron beam dosimetry using MOSFET detector.J Appl Clin Med Phys. 2010 Oct 4;12(1):3267. doi: 10.1120/jacmp.v12i1.3267. J Appl Clin Med Phys. 2010. PMID: 21330970 Free PMC article.
-
Toward a real-time in vivo dosimetry system using plastic scintillation detectors.Int J Radiat Oncol Biol Phys. 2010 Sep 1;78(1):280-7. doi: 10.1016/j.ijrobp.2009.11.025. Epub 2010 Mar 16. Int J Radiat Oncol Biol Phys. 2010. PMID: 20231074 Free PMC article.
References
-
- Rowbottom CG, Jaffray DA. Characteristics and performance of a micro‐MOSFET: an “imageable” dosimeter for image‐guided radiotherapy. Med Phys. 2004;31(3):609–615. - PubMed
-
- Jornet N, Carrasco P, Jurado D, Ruiz A, Eudaldo T, Ribas M. Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV X‐ray beams. Med Phys. 2004;31(9):2534–2542. - PubMed
-
- Scarantino CW, Ruslander DM, Rini CJ, Mann GG, Nagle HT, Black RD. An implantable radiation dosimeter for use in external beam radiation therapy. Med Phys. 2004;31(9):2658–2671. - PubMed
-
- Cygler JE, Saoudi A, Perry G, Hallil A, Brown M, Thomson I. Measurement of urethral dose profiles in prostate brachytherapy using a linear MOSFET array dosimeter. Radiother Oncol. 2004;71(Suppl 2):592–593.
-
- Beddar AS, Salehpour M, Briere TM, Hamidian H, Gillin MT. Preliminary evaluation of implantable MOSFET radiation dosimeters. Phys Med Biol. 2005;50(1):141–149. - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources