Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Mar;401(1-2):14-9.
doi: 10.1016/j.cca.2008.10.032. Epub 2008 Nov 9.

HPLC analysis of asymmetric dimethylarginine (ADMA) and related arginine metabolites in human plasma using a novel non-endogenous internal standard

Affiliations

HPLC analysis of asymmetric dimethylarginine (ADMA) and related arginine metabolites in human plasma using a novel non-endogenous internal standard

Scott Blackwell et al. Clin Chim Acta. 2009 Mar.

Abstract

Background: Asymmetric dimethylarginine (ADMA) is an endogenous inhibitor of nitric oxide synthesis which has been implicated in the endothelial dysfunction. Methods for ADMA measurement often yield widely differing results, and few methods simultaneously offer satisfactory accuracy and precision. We describe a fully validated HPLC method for analysis of arginine and its methylated derivatives in human plasma using a novel internal standard.

Methods: Arginine and related metabolites are extracted from plasma by solid phase extraction (SPE), derivatised with ortho-phthaldialdehyde and separated by isocratic reverse phase chromatography. Monoethylarginine (MEA), which is not endogenously present in human plasma was used as internal standard. SPE and chromatographic procedures are optimised and recovery, precision, linearity and sensitivity of the assay established. The suitability and performance of MEA is compared with that of monomethylarginine (MMA), the internal standard most commonly used in HPLC methods.

Results: SPE yields high and reproducible recoveries (>90%). The analytes of interest are chromatographically well resolved. The method has high sensitivity (LOD, 0.01 micromol/L for arginine and 0.001 micromol/L for ADMA, SDMA and homoarginine) and good precision (CV, 2.5% for ADMA). The data obtained with the internal standards MEA and MMA is comparable in terms of assay precision and population reference intervals.

Conclusions: We describe an optimised isocratic HPLC method for the simultaneous measurement of arginine and related metabolites in plasma which exhibits satisfactory precision and is suitable for routine use. Its main advantage over other published HPLC methods is the use of the novel internal standard, MEA, which unlike other commonly used internal standards is not inherent in human plasma.

PubMed Disclaimer

LinkOut - more resources