Cardiac screening by STIC: can sonologists performing the 20-week anomaly scan pick up outflow tract abnormalities by scrolling the A-plane of STIC volumes?
- PMID: 19035539
- DOI: 10.1002/uog.6261
Cardiac screening by STIC: can sonologists performing the 20-week anomaly scan pick up outflow tract abnormalities by scrolling the A-plane of STIC volumes?
Abstract
Objective: To assess whether medically qualified sonologists with low-to-intermediate scanning experience are able to detect major abnormalities of the outflow tracts by reviewing the A-plane of cardiac volume datasets acquired with spatiotemporal image correlation (STIC).
Methods: Fourteen sonologists of low-to-intermediate scanning experience were recruited among residents and colleagues involved in the screening ultrasound clinic at our referral center. Basic criteria for selection were: ability to perform the 20-week anomaly scan and to assess the four-chamber view, inability to perform extended cardiac screening (outflows); willingness to participate in the study. These sonologists attended a 2-hour lesson on: a) how the outflow tract views can be abnormal, and b) how to use a laptop and the dedicated software to review cardiac volumes in the A-plane only. After this briefing, each of them, independently, reviewed 26 preselected volumes at a workstation (from 16 normal fetuses and 10 with outflow tract abnormalities), without knowing how many of them were normal. After reviewing each volume, the sonologist was asked to define the outflow tract views as normal or abnormal and, if willing, to hypothesize the anomaly. The sequence of cases was changed for each participant. The time allotted for review of the volumes was 1 hour (about 2 min per case).
Results: Of the 364 diagnoses from review of the volumes, 116 (31.9%) were true positives, 195 (53.6%) were true negatives, 29 (8.0%) were false positives and 24 (6.6%) were false negatives. The sensitivity, specificity and positive and negative predictive values were 83%, 87%, 80% and 89%, respectively. Individual diagnostic accuracy ranged from 66 to 100% (median, 85.5%) and individual detection rate from 50 to 100% (median, 85%). The detection rate per single congenital heart disease ranged from 50% (for TGA with intact ventricular septum) to 100% (for DORV, DORV with pulmonary atresia and TGA with ventricular septal defect). There was no correlation between detection rate and alignment of the four-chamber view with the ultrasound beam (apical vs. transverse).
Conclusions: In this preliminary study, we have demonstrated that sonologists with low-to-intermediate experience of anomaly ultrasound screening in the second trimester and no experience of insonating the outflow tracts were able to identify outflow tract abnormalities by reviewing the A-plane of cardiac volume datasets, after detailed briefing.
(c) 2008 ISUOG.
Comment in
-
How best to improve antenatal detection of congenital heart defects.Ultrasound Obstet Gynecol. 2008 Dec;32(7):846-8. doi: 10.1002/uog.6279. Ultrasound Obstet Gynecol. 2008. PMID: 19035540 No abstract available.
Similar articles
-
Use of spatiotemporal image correlation at 11-14 weeks' gestation.Ultrasound Obstet Gynecol. 2013 Dec;42(6):669-78. doi: 10.1002/uog.12548. Ultrasound Obstet Gynecol. 2013. PMID: 23801593
-
Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation.Am J Obstet Gynecol. 2003 Dec;189(6):1792-802. doi: 10.1016/s0002-9378(03)00913-x. Am J Obstet Gynecol. 2003. PMID: 14710117
-
Feasibility and accuracy of fetal echocardiography using four-dimensional spatiotemporal image correlation technology before 16 weeks' gestation.Ultrasound Obstet Gynecol. 2009 Jun;33(6):645-51. doi: 10.1002/uog.6374. Ultrasound Obstet Gynecol. 2009. PMID: 19479815
-
First-trimester ultrasound detection of fetal heart anomalies: systematic review and meta-analysis.Ultrasound Obstet Gynecol. 2022 Jan;59(1):11-25. doi: 10.1002/uog.23740. Ultrasound Obstet Gynecol. 2022. PMID: 34369613 Free PMC article.
-
The fetal heart: a practical sonographic approach.Semin Ultrasound CT MR. 1996 Feb;17(1):15-33. doi: 10.1016/s0887-2171(96)90042-6. Semin Ultrasound CT MR. 1996. PMID: 8845190 Review.
Cited by
-
Fetal Intelligent Navigation Echocardiography (FINE) Detects 98% of Congenital Heart Disease.J Ultrasound Med. 2018 Nov;37(11):2577-2593. doi: 10.1002/jum.14616. Epub 2018 Mar 30. J Ultrasound Med. 2018. PMID: 29603310 Free PMC article.
-
Eleven fetal echocardiographic planes using 4-dimensional ultrasound with spatio-temporal image correlation (STIC): a logical approach to fetal heart volume analysis.Cardiovasc Ultrasound. 2010 Sep 15;8:41. doi: 10.1186/1476-7120-8-41. Cardiovasc Ultrasound. 2010. PMID: 20843340 Free PMC article.
-
Three- and four-dimensional ultrasound in fetal echocardiography: an up-to-date overview.J Perinatol. 2016 Sep;36(9):685-93. doi: 10.1038/jp.2016.23. Epub 2016 Mar 10. J Perinatol. 2016. PMID: 26963426 Review.
-
A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views.Fetal Diagn Ther. 2017;41(2):89-99. doi: 10.1159/000446982. Epub 2016 Jun 17. Fetal Diagn Ther. 2017. PMID: 27309391 Free PMC article.
-
Novel foetal echocardiographic image processing software (5D Heart) improves the display of key diagnostic elements in foetal echocardiography.BMC Med Imaging. 2020 Apr 3;20(1):33. doi: 10.1186/s12880-020-00429-8. BMC Med Imaging. 2020. PMID: 32245426 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical