Diffeomorphic demons: efficient non-parametric image registration
- PMID: 19041946
- DOI: 10.1016/j.neuroimage.2008.10.040
Diffeomorphic demons: efficient non-parametric image registration
Abstract
We propose an efficient non-parametric diffeomorphic image registration algorithm based on Thirion's demons algorithm. In the first part of this paper, we show that Thirion's demons algorithm can be seen as an optimization procedure on the entire space of displacement fields. We provide strong theoretical roots to the different variants of Thirion's demons algorithm. This analysis predicts a theoretical advantage for the symmetric forces variant of the demons algorithm. We show on controlled experiments that this advantage is confirmed in practice and yields a faster convergence. In the second part of this paper, we adapt the optimization procedure underlying the demons algorithm to a space of diffeomorphic transformations. In contrast to many diffeomorphic registration algorithms, our solution is computationally efficient since in practice it only replaces an addition of displacement fields by a few compositions. Our experiments show that in addition to being diffeomorphic, our algorithm provides results that are similar to the ones from the demons algorithm but with transformations that are much smoother and closer to the gold standard, available in controlled experiments, in terms of Jacobians.
Similar articles
-
Non-parametric diffeomorphic image registration with the demons algorithm.Med Image Comput Comput Assist Interv. 2007;10(Pt 2):319-26. doi: 10.1007/978-3-540-75759-7_39. Med Image Comput Comput Assist Interv. 2007. PMID: 18044584
-
Insight into efficient image registration techniques and the demons algorithm.Inf Process Med Imaging. 2007;20:495-506. doi: 10.1007/978-3-540-73273-0_41. Inf Process Med Imaging. 2007. PMID: 17633724
-
Medical image registration by combining global and local information: a chain-type diffeomorphic demons algorithm.Phys Med Biol. 2013 Dec 7;58(23):8359-78. doi: 10.1088/0031-9155/58/23/8359. Epub 2013 Nov 11. Phys Med Biol. 2013. PMID: 24217008
-
Symmetric log-domain diffeomorphic Registration: a demons-based approach.Med Image Comput Comput Assist Interv. 2008;11(Pt 1):754-61. doi: 10.1007/978-3-540-85988-8_90. Med Image Comput Comput Assist Interv. 2008. PMID: 18979814
-
A momentum-based diffeomorphic demons framework for deformable MR-CT image registration.Phys Med Biol. 2018 Oct 24;63(21):215006. doi: 10.1088/1361-6560/aae66c. Phys Med Biol. 2018. PMID: 30353886 Free PMC article.
Cited by
-
Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms.J Appl Clin Med Phys. 2013 Jul 8;14(4):4247. doi: 10.1120/jacmp.v14i4.4247. J Appl Clin Med Phys. 2013. PMID: 23835389 Free PMC article.
-
Multi-atlas segmentation of biomedical images: A survey.Med Image Anal. 2015 Aug;24(1):205-219. doi: 10.1016/j.media.2015.06.012. Epub 2015 Jul 6. Med Image Anal. 2015. PMID: 26201875 Free PMC article. Review.
-
HippoBellum: Acute Cerebellar Modulation Alters Hippocampal Dynamics and Function.J Neurosci. 2020 Sep 2;40(36):6910-6926. doi: 10.1523/JNEUROSCI.0763-20.2020. Epub 2020 Aug 7. J Neurosci. 2020. PMID: 32769107 Free PMC article.
-
Content representation in the human medial temporal lobe.Cereb Cortex. 2013 Jan;23(1):80-96. doi: 10.1093/cercor/bhr379. Epub 2012 Jan 23. Cereb Cortex. 2013. PMID: 22275474 Free PMC article.
-
Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction.Med Phys. 2013 Mar;40(3):031710. doi: 10.1118/1.4790689. Med Phys. 2013. PMID: 23464305 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources