Validation of finite element predictions of cartilage contact pressure in the human hip joint
- PMID: 19045515
- PMCID: PMC2840996
- DOI: 10.1115/1.2953472
Validation of finite element predictions of cartilage contact pressure in the human hip joint
Abstract
Methods to predict contact stresses in the hip can provide an improved understanding of load distribution in the normal and pathologic joint. The objectives of this study were to develop and validate a three-dimensional finite element (FE) model for predicting cartilage contact stresses in the human hip using subject-specific geometry from computed tomography image data, and to assess the sensitivity of model predictions to boundary conditions, cartilage geometry, and cartilage material properties. Loads based on in vivo data were applied to a cadaveric hip joint to simulate walking, descending stairs, and stair-climbing. Contact pressures and areas were measured using pressure sensitive film. CT image data were segmented and discretized into FE meshes of bone and cartilage. FE boundary and loading conditions mimicked the experimental testing. Fair to good qualitative correspondence was obtained between FE predictions and experimental measurements for simulated walking and descending stairs, while excellent agreement was obtained for stair-climbing. Experimental peak pressures, average pressures, and contact areas were 10.0 MPa (limit of film detection), 4.4-5.0 MPa, and 321.9-425.1 mm(2), respectively, while FE-predicted peak pressures, average pressures, and contact areas were 10.8-12.7 MPa, 5.1-6.2 MPa, and 304.2-366.1 mm(2), respectively. Misalignment errors, determined as the difference in root mean squared error before and after alignment of FE results, were less than 10%. Magnitude errors, determined as the residual error following alignment, were approximately 30% but decreased to 10-15% when the regions of highest pressure were compared. Alterations to the cartilage shear modulus, bulk modulus, or thickness resulted in +/-25% change in peak pressures, while changes in average pressures and contact areas were minor (+/-10%). When the pelvis and proximal femur were represented as rigid, there were large changes, but the effect depended on the particular loading scenario. Overall, the subject-specific FE predictions compared favorably with pressure film measurements and were in good agreement with published experimental data. The validated modeling framework provides a foundation for development of patient-specific FE models to investigate the mechanics of normal and pathological hips.
Figures
References
-
- Felson DT, Lawrence RC, Dieppe PA, Hirsch R, Helmick CG, Jordan JM, Kington RS, Lane NE, Nevitt MC, Zhang Y, Sowers M, McAlindon T, Spector TD, Poole AR, Yanovski SZ, Ateshian G, Sharma L, Buckwalter JA, Brandt KD, Fries JF. Osteoarthritis: New Insights. Part 1: The Disease and Its Risk Factors. Ann Intern Med. 2000;133:635–46. - PubMed
-
- Mankin HJ. The Reaction of Articular Cartilage to Injury and Osteoarthritis (Second of Two Parts) N Engl J Med. 1974;291:1335–40. - PubMed
-
- Mankin HJ. The Reaction of Articular Cartilage to Injury and Osteoarthritis (First of Two Parts) N Engl J Med. 1974;291:1285–92. - PubMed
-
- Mow VC, Setton LA, Guilak F, Ratcliffe A. Osteoarthritic Disorders. American Academy of Orthopaedic Surgeons; 1995. Mechanical Factors in Articular Cartilage and Their Role in Osteoarthritis.
-
- Poole AR. Osteoarthritic Disorders. American Academy of Orthopaedic Surgeons; 1995. Imbalances of Anabolism and Catabolism of Cartilage Matrix Components in Osteoarthritis.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
