Abstract The use of continuous subcutaneous insulin infusion (CSII) pumps has been gaining popularity since 1979, when the first research report on insulin pumps was published. Insulin pumps-small medical devices that are programmed to infuse insulin through a catheter placed under the skin-are a replacement for multiple daily injections of insulin. They are currently being used by 375,000 people with type 1 diabetes, many of whom prefer CSII to multiple daily injections because of the increased flexibility of diet and exercise, increased convenience and precision when dosing, and better predictability of blood glucose levels that insulin pumps can provide when used correctly. Recent pump manufacturers have engineered a new feature called a bolus calculator, which calculates bolus insulin doses based on input from the pump wearer, which functions to help patients obtain optimum control over blood glucose levels. The bolus calculator takes into account the patient's current blood glucose, target blood glucose, amount of carbohydrate consumed, and other factors such as insulin sensitivity and insulin-to-carbohydrate ratio as well as duration of insulin action ("insulin on board"). Each pump company calculates insulin doses in a slightly different way. This article will review differences in bolus calculator recommendations between four insulin pumps, as well as errors that may occur when using bolus calculators. It will also include an in silico simulation of a meal followed by a snack using multiple insulin decay curves.
Similar articles
-
A bolus calculator is an effective means of controlling postprandial glycemia in patients on insulin pump therapy.Diabetes Technol Ther. 2003;5(3):365-9. doi: 10.1089/152091503765691848. Diabetes Technol Ther. 2003. PMID: 12828818 Clinical Trial.
-
Benefits of a bolus calculator in pre- and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII).Diabet Med. 2008 Sep;25(9):1036-42. doi: 10.1111/j.1464-5491.2008.02549.x. Diabet Med. 2008. PMID: 18937673 Clinical Trial.
-
The dual-wave bolus feature in continuous subcutaneous insulin infusion pumps controls prolonged post-prandial hyperglycaemia better than standard bolus in Type 1 diabetes.Diabetes Nutr Metab. 2004 Aug;17(4):211-6. Diabetes Nutr Metab. 2004. PMID: 15575341 Clinical Trial.
-
[Present role of continuous subcutaneous insulin infusion (CSII) by insulin pump in the treatment of diabetes mellitus].Schweiz Med Wochenschr. 2000 Dec 2;130(48):1854-61. Schweiz Med Wochenschr. 2000. PMID: 11132530 Review. German.
-
The education of patients in prandial insulin dosing related to the structure of bolus calculators.Pediatr Endocrinol Diabetes Metab. 2010;16(4):301-5. Pediatr Endocrinol Diabetes Metab. 2010. PMID: 21447273 Review.
Cited by
-
Glucose clamp algorithms and insulin time-action profiles.J Diabetes Sci Technol. 2009 Sep 1;3(5):1005-13. doi: 10.1177/193229680900300503. J Diabetes Sci Technol. 2009. PMID: 20144413 Free PMC article. Review.
-
Automatic data processing to achieve a safe telemedical artificial pancreas.J Diabetes Sci Technol. 2009 Sep 1;3(5):1039-46. doi: 10.1177/193229680900300507. J Diabetes Sci Technol. 2009. PMID: 20144417 Free PMC article.
-
Absorption patterns of meals containing complex carbohydrates in type 1 diabetes.Diabetologia. 2013 May;56(5):1108-17. doi: 10.1007/s00125-013-2852-x. Epub 2013 Feb 23. Diabetologia. 2013. PMID: 23435829
-
Practical use of self-monitoring of blood glucose data.J Diabetes Sci Technol. 2013 Mar 1;7(2):532-41. doi: 10.1177/193229681300700229. J Diabetes Sci Technol. 2013. PMID: 23567011 Free PMC article. Review.
-
Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".J Diabetes Sci Technol. 2012 Mar 1;6(2):345-7. doi: 10.1177/193229681200600219. J Diabetes Sci Technol. 2012. PMID: 22538145 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical