Localization of implanted dipoles by magnetoencephalography
- PMID: 1906146
- DOI: 10.1212/wnl.41.7.1072
Localization of implanted dipoles by magnetoencephalography
Abstract
We attempted to validate the location of sources predicted by magnetoencephalography (MEG) by studying 19 specially designed dipole electrodes implanted in six patients with intractable partial seizures who were undergoing subdural electrode recording. We used a seven-channel magnetometer to measure the magnetic fields produced by passing through the dipoles a 40-microA, 5-msec square-wave pulse followed 40 msec later by a pulse of opposite polarity; 200 pulses were averaged for each magnetometer position. The actual dipole locations were measured from skull radiographs, and we based MEG localization on a spherical head model with the inclusion of volume currents. MEG estimates of the sources were within several centimeters (mean, 1.69 cm) of the measured locations. We conclude that MEG localization was promising.
Similar articles
-
EEG and MEG source analysis of single and averaged interictal spikes reveals intrinsic epileptogenicity in focal cortical dysplasia.Epilepsia. 2004 Jun;45(6):621-31. doi: 10.1111/j.0013-9580.2004.56503.x. Epilepsia. 2004. PMID: 15144427
-
Magnetoencephalography-directed surgery in patients with neocortical epilepsy.J Neurosurg. 2002 Oct;97(4):865-73. doi: 10.3171/jns.2002.97.4.0865. J Neurosurg. 2002. PMID: 12405375 Clinical Trial.
-
MEG versus EEG localization test using implanted sources in the human brain.Ann Neurol. 1990 Dec;28(6):811-7. doi: 10.1002/ana.410280613. Ann Neurol. 1990. PMID: 2285267
-
Localization of partial epilepsy using magnetic and electric measurements.Epilepsia. 1991;32 Suppl 5:S29-40. Epilepsia. 1991. PMID: 1743168 Review.
-
[Functional imaging of the brain. Magnetoencephalography (MEG)].Radiologe. 1993 Nov;33(11):633-8. Radiologe. 1993. PMID: 8278590 Review. German.
Cited by
-
EEG versus MEG localization accuracy: theory and experiment.Brain Topogr. 1991 Winter;4(2):95-103. doi: 10.1007/BF01132766. Brain Topogr. 1991. PMID: 1793693 Review.
-
Can magnetoencephalography aid epilepsy surgery?Epilepsy Curr. 2008 Jan-Feb;8(1):1-5. doi: 10.1111/j.1535-7511.2007.00215.x. Epilepsy Curr. 2008. PMID: 18265877 Free PMC article.
-
Simultaneous EEG and MEG source reconstruction in sparse electromagnetic source imaging.Hum Brain Mapp. 2013 Apr;34(4):775-95. doi: 10.1002/hbm.21473. Epub 2011 Nov 18. Hum Brain Mapp. 2013. PMID: 22102512 Free PMC article.
-
Magnetoencephalography: clinical application in epilepsy.Curr Neurol Neurosci Rep. 2003 Jul;3(4):341-8. doi: 10.1007/s11910-003-0012-2. Curr Neurol Neurosci Rep. 2003. PMID: 12930705 Review.
-
In vivo validation of distributed source solutions for the biomagnetic inverse problem.Brain Topogr. 1993 Spring;5(3):263-73. doi: 10.1007/BF01128993. Brain Topogr. 1993. PMID: 8507552
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources