Pressure-dependent hydrometra dimensions in hysteroscopy
- PMID: 19067060
- DOI: 10.1007/s00464-008-0231-3
Pressure-dependent hydrometra dimensions in hysteroscopy
Abstract
Aim: To investigate the relation between intrauterine pressures and volumes for virtual-reality-based surgical training in hysteroscopy.
Material and methods: Ten fresh extirpated uteri were insufflated by commercial hysteroscopy pump and imaged by computer tomography (CT) under intrauterine air pressure in distension-collapse cycles between 0 , 20 (150 mmHg), and 0 kPa, performing a CT scan at every step at about 2.7 kPa (20 mmHg).
Results: An initial threshold pressure to distend the cavity was avoided by introducing the insufflation tube up to the fundus. The filling and release phases of seven uteri that were completely distended showed the typical characteristics of a hysteresis curve which is expected from a viscoelastic, nonlinear, anisotropic soft tissue organ like the uterus. In three cases tightening the extirpated uterus especially at the lateral resection lines caused significant problems that inhibited registration of a complete distension-collapse cycle. Interpolated volumes for complete distended cavities and extrapolated for incomplete data sets, derived from the digitally reconstructed three-dimensional (3D) geometries, ranged from 0.6 to 11.4 mL at 20 kPa. These values highly correlate with the uterine volume (not insufflated) considering different biometric data of the uteri and patient data. Linear (R(2) = 0.66) and quadratic least-squares fits (R(2) = 0.74) were used to derive the formulas y = 0.069x and y = 0.00037x(2) + 0.036x, where x is the uterine volume in mL (not insufflated) and y is the cavity volume in mL at 20 kPa intrauterine pressure.
Conclusions: Our experimental hysteroscopical setup enabled us to reconstruct the changes in volumes of insufflated uteri under highly realistic conditions in 3D. The relation between intrauterine pressure and cavity volume in distension-collapse cycles describes a typical hysteresis curve.
Similar articles
-
Using statistical shape analysis for the determination of uterine deformation states during hydrometra.Med Image Comput Comput Assist Interv. 2007;10(Pt 2):858-65. doi: 10.1007/978-3-540-75759-7_104. Med Image Comput Comput Assist Interv. 2007. PMID: 18044649
-
A finite element model for the simulation of hydrometra.Technol Health Care. 2004;12(3):259-67. Technol Health Care. 2004. PMID: 15328454
-
Optimum uterine filling pressure for outpatient diagnostic hysteroscopy: a double-blind, randomized controlled trial.Reprod Biomed Online. 2014 Jan;28(1):86-91. doi: 10.1016/j.rbmo.2013.07.018. Epub 2013 Sep 14. Reprod Biomed Online. 2014. PMID: 24262433 Clinical Trial.
-
Distension media delivery systems in hysteroscopy: past, present and future.Minim Invasive Ther Allied Technol. 2022 Jan;31(1):1-12. doi: 10.1080/13645706.2020.1763402. Epub 2020 May 15. Minim Invasive Ther Allied Technol. 2022. PMID: 32410478 Review.
-
Media and delivery systems.Obstet Gynecol Clin North Am. 1995 Sep;22(3):409-22. Obstet Gynecol Clin North Am. 1995. PMID: 8524528 Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources