Comparison of automated 4D-MSPECT and visual analysis for evaluating myocardial perfusion in coronary artery disease
- PMID: 19073376
- PMCID: PMC11918208
- DOI: 10.1016/S1607-551X(09)70001-4
Comparison of automated 4D-MSPECT and visual analysis for evaluating myocardial perfusion in coronary artery disease
Abstract
The aim of this study was to assess the reproducibility and diagnostic performance for coronary artery disease (CAD) of an automated software package, 4D-MSPECT, and compare the results with a visual approach. We enrolled 60 patients without previously known CAD, who underwent dual-isotope rest Tl-201/stress Tc-99m sestamibi myocardial perfusion imaging and subsequent coronary angiography within 3 months. The automated summed stress score (A-SSS), summed rest score (A-SRS) and summed difference score (A-SDS) were obtained using a 17-segment five-point scale model with 4D-MSPECT. For intraobserver and interobserver variability assessment, automated scoring was done by a nuclear medicine physician twice and by a nuclear medicine technologist. The visual summed stress score (V-SSS), summed rest score (V-SRS), and summed difference score (V-SDS) were obtained by consensus of two nuclear medicine physicians. The intraobserver and interobserver agreements of automated segmental scores were excellent. The intraobserver and interobserver summed scores also correlated well. Agreements between visual and automated segmental scores were moderate (weighted kappa of 0.55 and 0.50 for stress and rest images, respectively). Correlations between automated and visual summed scores were high, with correlation coefficients of 0.89, 0.85 and 0.82 for SSS, SRS and SDS, respectively (all p < 0.001). The receiver operating characteristic area under the curve for diagnosis of CAD by V-SSS, V-SDS, A-SSS and A-SDS were 0.78 +/- 0.06, 0.87 +/- 0.05, 0.84 +/- 0.05 and 0.90 +/- 0.04, respectively. A-SDS had better diagnostic performance than A-SSS and V-SSS (p = 0.043 and p = 0.032, respectively), whereas there was no statistically significant difference between A-SDS and V-SDS (p = 0.56). Using V-SDS > or = 2 as a diagnostic threshold, the sensitivity, specificity, and accuracy for CAD were 83.7%, 76.5% and 81.7%, respectively. Using A-SDS > or = 3 as a diagnostic threshold, the sensitivity, specificity, and accuracy for CAD were 79.1%, 82.4% and 80.0%, respectively. In conclusion, the reproducibility of automated semiquantitative analysis with 4D-MSPECT was excellent. The diagnostic performance of automated semiquantitative analysis with 4D-MSPECT was comparable with the visual approach.
Similar articles
-
Comparison of SSS and SRS calculated from normal databases provided by QPS and 4D-MSPECT manufacturers and from identical institutional normals.Eur J Nucl Med Mol Imaging. 2008 Feb;35(2):311-8. doi: 10.1007/s00259-007-0600-5. Epub 2007 Oct 9. Eur J Nucl Med Mol Imaging. 2008. PMID: 17922271
-
Diagnostic value of automated quantification of nuclear cardiology in Japanese patients with single vessel coronary artery disease: comparison between Japanese and American normal databases.J Cardiol. 2013 Oct;62(4):224-9. doi: 10.1016/j.jjcc.2013.04.001. Epub 2013 May 31. J Cardiol. 2013. PMID: 23731920
-
Automated Analysis vs. Expert Reading in Nuclear Cardiology: Correlations with the Angiographic Score.Medicina (Kaunas). 2022 Oct 11;58(10):1432. doi: 10.3390/medicina58101432. Medicina (Kaunas). 2022. PMID: 36295592 Free PMC article.
-
Automated SPECT analysis compared with expert visual scoring for the detection of FFR-defined coronary artery disease.Eur J Nucl Med Mol Imaging. 2018 Jul;45(7):1091-1100. doi: 10.1007/s00259-018-3951-1. Epub 2018 Feb 22. Eur J Nucl Med Mol Imaging. 2018. PMID: 29470616 Free PMC article.
-
Diagnostic value of ischemia severity at myocardial perfusion imaging in elderly persons with suspected coronary disease.J Cardiovasc Med (Hagerstown). 2016 Oct;17(10):719-28. doi: 10.2459/JCM.0000000000000339. J Cardiovasc Med (Hagerstown). 2016. PMID: 26599683
Cited by
-
Transient ischemic dilatation ratio derived from myocardial perfusion scintigraphy: What are we looking at?J Nucl Cardiol. 2010 Apr;17(2):207-15. doi: 10.1007/s12350-009-9180-z. Epub 2009 Dec 25. J Nucl Cardiol. 2010. PMID: 20035391
-
Relationship between Semi-Quantitative Parameters of Thallium-201 Myocardial Perfusion Imaging and Coronary Artery Disease.Diagnostics (Basel). 2020 Sep 30;10(10):772. doi: 10.3390/diagnostics10100772. Diagnostics (Basel). 2020. PMID: 33007898 Free PMC article.
-
Myocardial regeneration after implantation of porcine small intestinal submucosa in the left ventricle.Rev Bras Cir Cardiovasc. 2014 Apr-Jun;29(2):202-13. doi: 10.5935/1678-9741.20140070. Rev Bras Cir Cardiovasc. 2014. PMID: 25140470 Free PMC article.
References
-
- Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest thallium‐201/stress technetium‐99m sestamibi dual‐isotope myocardial perfusion singlephoton emission computed tomography: a clinical validation study. J Am Coll Cardiol. 1993; 22: 1455–1464. - PubMed
-
- Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. Circulation. 2002; 105: 539–542. - PubMed
-
- Berman DS, Abidov A, Kang X, et al. Prognostic validation of a 17‐segment score derived from a 20‐segment score for myocardial perfusion SPECT interpretation. J Nucl Cardiol. 2004; 11: 414–423. - PubMed
-
- Hansen CL, Goldstein RA, Akinboboye OO, et al. Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol. 2007; 14: e39–e60. - PubMed