Comparative Study
. 1991 Jun;29(6):1232-5.
doi: 10.1128/jcm.29.6.1232-1235.1991.

Detection of enterococcal high-level aminoglycoside resistance with MicroScan freeze-dried panels containing newly modified medium and Vitek Gram-Positive Susceptibility cards

Affiliations
Comparative Study

Detection of enterococcal high-level aminoglycoside resistance with MicroScan freeze-dried panels containing newly modified medium and Vitek Gram-Positive Susceptibility cards

D Weissmann et al. J Clin Microbiol. 1991 Jun.

Abstract

Both conventional and modified MicroScan Type 5 panels and Vitek Gram-Positive Susceptibility cards were compared with agar dilution screen plates for their abilities to detect high-level resistance to gentamicin and streptomycin in 235 enterococcal isolates, including 167 Enterococcus faecalis and 63 E. faecium isolates. The modified Type 5 panels contained dextrose-phosphate broth instead of Mueller-Hinton broth in their high-level-resistance screen wells. The sensitivities for detection of gentamicin and streptomycin high-level resistance were 100 and 100% (E. faecalis) and 100 and 94% (E. faecium) for the modified MicroScan panels, 100 and 89% (E. faecalis) and 100 and 98% (E. faecium) for the conventional MicroScan panels, and 81 and 86% (E. faecalis) and 85 and 94% (E. faecium) for the Vitek cards. All specificities were 100% except for the Vitek cards with streptomycin, where it was 96%. Isolates that showed resistance on the streptomycin agar screen plates were rescreened on plates containing 32,000 micrograms/ml to detect ribosomally mediated resistance. For all three systems, every failure to detect streptomycin high-level resistance occurred in isolates with enzymatic, not ribosomal, resistance. The modified MicroScan Type 5 panels are a suitable method for detecting enterococcal high-level resistance to gentamicin and streptomycin. The Vitek cards are too insensitive for this purpose.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ann Intern Med. 1987 May;106(5):757-61 - PubMed
    1. Arch Intern Med. 1976 Aug;136(8):883-6 - PubMed
    1. J Antimicrob Chemother. 1989 Jul;24(1):63-8 - PubMed
    1. Rev Infect Dis. 1989 Jan-Feb;11(1):74-85 - PubMed
    1. Arch Intern Med. 1987 Sep;147(9):1591-4 - PubMed

Publication types

MeSH terms

LinkOut - more resources