Radiosurgery with unflattened 6-MV photon beams
- PMID: 1908047
- DOI: 10.1118/1.596656
Radiosurgery with unflattened 6-MV photon beams
Abstract
One of the major drawbacks to doing stereotactic radiosurgery with a linear accelerator is the long time required to deliver the target dose. Single fractions of 25 Gy delivered at the isocenter and at depth in the skull may require beam times in excess of 15 min for a typical linear accelerator with a maximum dose rate of 250 cGy/min in tissue. In an effort to decrease the treatment time for this technique, the flattening filter has been removed from an AECL Therac-6 linear accelerator and the characteristics of the resulting beam have been measured. Flatness is acceptable for the field sizes used with this technique and the dose rate is increased by a factor of 2.75.
Similar articles
-
Dose distributions in dynamic stereotactic radiosurgery.Med Phys. 1987 Sep-Oct;14(5):780-9. doi: 10.1118/1.596003. Med Phys. 1987. PMID: 3119968
-
Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study.Appl Radiat Isot. 2007 Sep;65(9):1029-36. doi: 10.1016/j.apradiso.2007.04.023. Epub 2007 Jun 9. Appl Radiat Isot. 2007. PMID: 17616465
-
Treatment-planning study of prostate cancer intensity-modulated radiotherapy with a Varian Clinac operated without a flattening filter.Int J Radiat Oncol Biol Phys. 2007 Aug 1;68(5):1567-71. doi: 10.1016/j.ijrobp.2007.04.025. Epub 2007 Jun 4. Int J Radiat Oncol Biol Phys. 2007. PMID: 17544596
-
Radiosurgery with high energy photon beams: a comparison among techniques.Int J Radiat Oncol Biol Phys. 1989 Mar;16(3):857-65. doi: 10.1016/0360-3016(89)90506-3. Int J Radiat Oncol Biol Phys. 1989. PMID: 2493438 Review.
-
A comparison of techniques for stereotactic radiotherapy by linear accelerator based on 3-dimensional dose distributions.Radiother Oncol. 1991 Sep;22(1):29-35. doi: 10.1016/0167-8140(91)90066-p. Radiother Oncol. 1991. PMID: 1947210 Review.
Cited by
-
Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy.J Appl Clin Med Phys. 2013 May 6;14(3):4126. doi: 10.1120/jacmp.v14i3.4126. J Appl Clin Med Phys. 2013. PMID: 23652246 Free PMC article.
-
Dose accuracy improvement on head and neck VMAT treatments by using the Acuros algorithm and accurate FFF beam calibration.Rep Pract Oncol Radiother. 2021 Feb 25;26(1):73-85. doi: 10.5603/RPOR.a2021.0014. eCollection 2021. Rep Pract Oncol Radiother. 2021. PMID: 33948305 Free PMC article.
-
Structural Shielding Design of a 6 MV Flattening Filter Free Linear Accelerator: Indian Scenario.J Med Phys. 2017 Jan-Mar;42(1):18-24. doi: 10.4103/jmp.JMP_99_16. J Med Phys. 2017. PMID: 28405104 Free PMC article.
-
The effects of flattening filter-free beams and aperture shape controller on the complexity of conventional large-field treatment plans.J Appl Clin Med Phys. 2023 Nov;24(11):e14108. doi: 10.1002/acm2.14108. Epub 2023 Aug 1. J Appl Clin Med Phys. 2023. PMID: 37528683 Free PMC article.
-
Comparison of Measured and Monte Carlo Calculated Dose Distributions from Indigenously Developed 6 MV Flattening Filter Free Medical Linear Accelerator.J Med Phys. 2018 Jul-Sep;43(3):162-167. doi: 10.4103/jmp.JMP_58_18. J Med Phys. 2018. PMID: 30305773 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical