Sensitivity and reproducibility of conventional qualitative and quantitative PCR assays for detection of the t(14;18)(q32;q21) chromosomal translocation in biopsy material from patients with follicular lymphoma
- PMID: 19082502
Sensitivity and reproducibility of conventional qualitative and quantitative PCR assays for detection of the t(14;18)(q32;q21) chromosomal translocation in biopsy material from patients with follicular lymphoma
Abstract
Follicular lymphoma (FL) is characterized by the t(14;18)(q32;q21) chromosomal translocation which can be detected by polymerase chain reaction (PCR) in approximately 70% of cases. The aim of our retrospective study was to evaluate the sensitivity and the reproducibility of both conventional qualitative and quantitative PCR assays for detection of the t(14;18)(q32;q21) chromosomal translocation in biopsy material. Fifty-seven formalin-fixed, paraffin-embedded tumor lymph node (LN) specimens from 50 patients with FL were included in the study. Qualitative PCR was performed with primer sets specific for the MBR, far3'-MBR and the mcr regions, respectively. Quantitative PCR was performed using the LightCycler instrument and the LightCycler - t(14;18) Quantification Kit (MBR). The overall detection rate of the t(14;18) in our study (52.6%) was in accordance with the literature. Of the t(14;18)-positive cases, 49.1% had breakpoints within the MBR and only 3.5% had breakpoints within the mcr. The most sensitive method was LightCycler-based PCR with a detection rate of 47.4%, followed by MBR1,2 assay (43.9%). We observed good agreement between qualitative MBR1,2 and quantitative LightCycler-based assay with a slightly higher detection rate of the quantitative method. The sensitivities of both methods were in accordance with results from other studies. Since LightCycler-based assay detects only breakpoints within the MBR, qualitative PCR should be employed in routine diagnostic settings for detection of breakpoints within the mcr and far3'-MBR regions.
Similar articles
-
Interphase fluorescence in situ hybridization is more sensitive than BIOMED-2 polymerase chain reaction protocol in detecting IGH-BCL2 rearrangement in both fixed and frozen lymph node with follicular lymphoma.Hum Pathol. 2007 Feb;38(2):365-72. doi: 10.1016/j.humpath.2006.08.022. Epub 2006 Nov 28. Hum Pathol. 2007. PMID: 17134735
-
Detection of t(14;18) by PCR of IgH/BCL2 fusion gene in follicular lymphoma from archived cytological smears.Coll Antropol. 2010 Jun;34(2):425-9. Coll Antropol. 2010. PMID: 20698113
-
Evaluation of interphase fluorescence in situ hybridization for the t(14;18)(q32;q21) translocation in the diagnosis of follicular lymphoma on fine-needle aspirates: a comparison with flow cytometry immunophenotyping.Cancer. 2003 Dec 25;99(6):385-93. doi: 10.1002/cncr.11787. Cancer. 2003. PMID: 14681948 Clinical Trial.
-
[Detection of residual disease in follicular lymphomas using the PCR technique: importance of clono-specific probes].Bull Cancer. 1998 Oct;85(10):847-54. Bull Cancer. 1998. PMID: 9835862 Review. French.
-
Molecular diagnostics in follicular non-Hodgkin's lymphoma: a review.Semin Oncol. 2000 Dec;27(6 Suppl 12):42-52. Semin Oncol. 2000. PMID: 11226000 Review.
Cited by
-
Demonstration of array-based analysis for highly multiplexed PCR assays application to detection of IGH@-BCL2 translocations in FFPE follicular lymphoma specimens.J Mol Diagn. 2011 May;13(3):252-62. doi: 10.1016/j.jmoldx.2010.11.019. J Mol Diagn. 2011. PMID: 21497287 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials