. 2009 Jul;467(7):1765-72.
doi: 10.1007/s11999-008-0661-1. Epub 2008 Dec 12.

Wear is reduced in THA performed with highly cross-linked polyethylene

Affiliations

Wear is reduced in THA performed with highly cross-linked polyethylene

Burak Beksaç et al. Clin Orthop Relat Res. 2009 Jul.

Abstract

Highly cross-linked polyethylene (HCLPE) has been used extensively to decrease osteolysis and related implant failure in THA. We compared the wear rate of HCLPE and noncross-linked conventional PE (CPE) liners and the rate of radiographic calcar resorption and osteolysis in young patients (35-60 years of age) who underwent THA by one surgeon. Thirty-four patients (41 THAs) who received a hybrid THA using a HCLPE liner were match-paired for age, gender, body mass index, and diagnosis with a group of patients who underwent THA with identical implants but with a CPE liner. The minimum followup was 4 years (average, 5.3; range, 4-8 years). Using the Livermore measurement technique, the averages of total wear of the HCLPE and CPE liners were 0.01 mm (range, -0.23-0.4) and 0.64 mm (range, 0-1.7), respectively. The average annual wear was less for the HCLPE than the noncross-linked PE (0.002 mm, range, -0.05-0.1 versus 0.12 mm, range, 0-0.29, respectively). Four hips in the HCLPE group and 23 in the CPE group had calcar resorption measuring averages of 2.5 mm (range, 2-3) and 7.5 mm (range, 1.8-23.8), respectively. Periprosthetic osteolysis occurred in two and eight hips in the HCLPE and CPE groups, respectively. Longer followup is needed to determine if these findings will result in improved implant survivorship.

Level of evidence: Level III, therapeutic study.

PubMed Disclaimer

References

    1. Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP. Reduction of osteolysis with use of Marathon cross-linked polyethylene: a concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am. 2008;90:1487–1491. - DOI - PubMed
    1. Bradford L, Baker D, Ries MD, Pruitt LA. Fatigue crack propagation resistance of highly crosslinked polyethylene. Clin Orthop Relat Res. 2004;429:68–72. - DOI - PubMed
    1. Bragdon CR, Barrett S, Martell JM, Greene ME, Malchau H, Harris WH. Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up. J Arthroplasty. 2006;21:935–943. - DOI - PubMed
    1. Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, Malchau H. Minimum 6-year followup of highly cross-linked polyethylene in THA. Clin Orthop Relat Res. 2007;465:122–127. - PubMed
    1. Callaghan JJ, Cuckler JM, Huddleston JI, Galante JO. How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis? J Am Acad Orthop Surg. 2008;16(suppl 1):S33–S38. - PubMed

Publication types