Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment
- PMID: 19089211
- PMCID: PMC4327639
- DOI: 10.1590/s1678-77572008000200016
Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment
Abstract
The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora system (p<0.01). The measurements achieved by the investigated radiographic methods were clinically similar and they are thus equivalent. Changes in brightness and contrast of the images using Digora software improved the diagnosis.
References
-
- Borg E, Attaelmanan A, Grondahl HG. Subjective image quality of solid-state and photostimulable phosphor systems for digital intraoral radiography. Dentomaxillofac Radiol. 2000;29:70–75. - PubMed
-
- Cederberg RA, Tydwell E, Frederiksen NL, Benson BW. Endodontic working length assessment: comparinson of storage phosphor digital imaging and radiographic film. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;85:325–328. - PubMed
-
- Conover GL, Hildebolt CF, Yokoyama-Crothers N. Comparison of linear measurements made from storage phosphor and dental radiographs. Dentomaxillofac Radiol. 1996;25:268–273. - PubMed
-
- Emmott LF. The digital revolution, images and X-rays. N Y State Dent J. 2005;71:40–42. - PubMed
-
- Garcia AA, Navarro LF, Castelló VU, Laliga RM. Evaluation of a digital radiography to estimate working length. J Endod. 1997;23:363–365. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous