Comparative Study
. 1991 Jul;29(7):1439-46.
doi: 10.1128/jcm.29.7.1439-1446.1991.

Comparisons of standard curve-fitting methods to quantitate Neisseria meningitidis group A polysaccharide antibody levels by enzyme-linked immunosorbent assay

Affiliations
Comparative Study

Comparisons of standard curve-fitting methods to quantitate Neisseria meningitidis group A polysaccharide antibody levels by enzyme-linked immunosorbent assay

B D Plikaytis et al. J Clin Microbiol. 1991 Jul.

Abstract

We examined several of the more commonly used models (log-log, two forms of the logit-log, and the four-parameter logistic-log transformations) for forming standard or calibration curves by using a standardized enzyme-linked immunosorbent assay (ELISA). Assay range, accuracy, and error for each function were measured and compared. Antibody levels to Neisseria meningitidis group A polysaccharide were estimated by calculating antibody concentrations of a serially diluted standard reference serum of known concentration. Each function achieved a high squared correlation coefficient (r2 greater than 0.97), indicating a high degree of accuracy in forming the standard curves. However, when predicted antibody concentrations were compared with the known values, the log-log function exhibited the least precision, with extreme percentages of error occurring at several dilutions. A partially specified logit-log transformation performed better than the log-log model over a reduced range of standard dilutions. This indicated that a high r2 alone was not a reliable measure of the accuracy of the standard curve. Of the methods surveyed, the logistic-log and fully specified logit-log functions were the most accurate models for forming standard curves and for interpolating antibody concentrations from the standard curve. The accuracy of the fully specified logit-log function is highly dependent on the precise specification of two unknown quantities, the optical densities at zero and infinite concentrations, prior to fitting the model to a typical set of calibration data. The four-parameter logistic-log function was the preferred choice for quantitating N. meningitidis group A total polysaccharide antibody by using a standardized ELISA. The function does not require prespecification of any parameters before estimating the standard curve, and the four parameters are readily interpretable in terms of identifiable physical quantities. This model also has the advantage that it is easiest to visualize since it does not incorporate complex transformations of the optical density scale.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Immunol Methods. 1988 Jan 21;106(1):71-81 - PubMed
    1. J Immunol Methods. 1989 Jun 21;120(2):167-71 - PubMed
    1. J Clin Microbiol. 1984 Oct;20(4):672-6 - PubMed
    1. J Immunol Methods. 1987 Nov 5;103(2):189-94 - PubMed
    1. Am J Physiol. 1987 Mar;252(3 Pt 1):E357-64 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources