Comparative Study
. 2009 Feb;181(2):867-71.
doi: 10.1016/j.juro.2008.10.070. Epub 2008 Dec 17.

Comparison of manual and computer assisted ultrasonic guidance for transparenchymal percutaneous renal needle placement

Affiliations
Comparative Study

Comparison of manual and computer assisted ultrasonic guidance for transparenchymal percutaneous renal needle placement

Jason F Skenazy et al. J Urol. 2009 Feb.

Abstract

Purpose: We evaluated a novel computer based guidance system for deploying needles into the renal parenchyma. We compared it to current standards, including a fixed needle guide and a freehand technique.

Materials and methods: We performed an in vitro comparison followed by a porcine trial. The in vitro model consisted of a bath of ultrasound medium with suspended metallic targets. We compared the number of attempts and the time needed by the novel guide design with and without its software and a support arm vs the freehand approach. In the porcine model we tested the software guide with and without a support arm for targeting a 5 mm lesion embedded in the renal parenchyma. Impressions of difficulty, time, the number of attempts, needle tip visualization and needle tip divergence were documented.

Results: Compared to freehand targeting the software guide and support arm decreased the number of targeting attempts in the in vitro model from 4.8 to 1.6 (p <0.001) and decreased the time required from 31.8 to 11.4 seconds (p <0.001). In the porcine study needle tip visualization with the software and support arm received an average score of 1.3 vs 1.8 with the software guide alone (p = 0.04). Tip divergence received a score of 1.4 with the arm and 1.8 without it (p = 0.07). Overall contribution received a score of 1.4 with and without the support arm (p = 0.35).

Conclusions: Computer assisted needle deployment decreased the time and number of attempts required to successfully target simulated parenchymal lesions and also decreased the subjective difficulty inherent in the standard freehand approach.