A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers
- PMID: 19100591
- DOI: 10.1016/j.ultras.2008.10.012
A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers
Abstract
Optimization of efficiency in hyperthermia requires a precise and non-invasive estimation of internal distribution of temperature. Although there are several research trends for ultrasonic temperature estimation, efficient equipments for its use in the clinical practice are not still available. The main objective of this work was to research about the limitations and potential improvements of previously reported signal processing options in order to identify research efforts to facilitate their future clinical use as a thermal estimator. In this document, we have a critical analysis of potential performance of previous ultrasonic research trends for temperature estimation inside materials, using different processing techniques proposed in frequency, time and phase domains. It was carried out in phantom with scatterers, assessing at their specific applicability, linearity and limitations in hyperthermia range. Three complementary evaluation indexes: technique robustness, Mat-lab processing time and temperature resolution, with specific application protocols, were defined and employed for a comparative quantification of the behavior of the techniques. The average increment per degrees C and mm was identified for each technique (3 KHz/ degrees C in the frequency analysis, 0.02 rad/ degrees C in the phase domain, while increments in the time domain of only 1.6 ns/ degrees C were found). Their linearity with temperature rising was measured using linear and quadratic regressions and they were correlated with the obtained data. New improvements in time and frequency signal processing in order to reveal the potential thermal and spatial resolutions of these techniques are proposed and their subsequent improved estimation results are shown for simulated and measured A-scans registers. As an example of these processing novelties, an excellent potential resolution of 0.12 degrees C into hyperthermia range, with near-to-linear frequency dependence, could be achieved. Specifically defined "numerical" and physical multi-scatter phantoms are described, which mimic ultrasound velocity in tissues of about 1560 m/s @ 35 degrees C and have a quasi-uniform internal scattering structure designed to assure standard signal patterns adequate for processing comparisons in the same time and sound velocity conditions for all the techniques analyzed, and to obtain easily repeatable multi-pulse echo-patterns. A perfect lineal dependence (100% of correlation coefficient) between the unitary average increment measured by each technique and temperature rising was observed while working with simulated A-scan registers, where all the parameters are under an accurate control. Nevertheless a very small quadratic tendency appeared in the results obtained from experimental echo registers, which are more similar to a real tissues case. It would be an interesting future work to analyze the behavior of these techniques in real tissues in order to confirm or reject this light quadratic tendency. Finally, new methods were detailed and applied in order to precisely quantify the advantages of each estimation technique; their respective intrinsic limitations were also underlined.
Similar articles
-
On the possibility of non-invasive multilayer temperature estimation using soft-computing methods.Ultrasonics. 2010 Jan;50(1):32-43. doi: 10.1016/j.ultras.2009.07.005. Epub 2009 Jul 23. Ultrasonics. 2010. PMID: 19695653
-
Artefacts in intracavitary temperature measurements during regional hyperthermia.Phys Med Biol. 2007 Sep 7;52(17):5157-71. doi: 10.1088/0031-9155/52/17/004. Epub 2007 Aug 7. Phys Med Biol. 2007. PMID: 17762078
-
A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and measured 3-D temperature data sets.IEEE Trans Biomed Eng. 2005 Mar;52(3):505-19. doi: 10.1109/TBME.2004.843291. IEEE Trans Biomed Eng. 2005. PMID: 15759581
-
Non-invasive estimation of hyperthermia temperatures with ultrasound.Int J Hyperthermia. 2005 Sep;21(6):589-600. doi: 10.1080/02656730500159103. Int J Hyperthermia. 2005. PMID: 16147442 Review.
-
Quo vadis elasticity imaging?Ultrasonics. 2004 Apr;42(1-9):331-6. doi: 10.1016/j.ultras.2003.11.010. Ultrasonics. 2004. PMID: 15047307 Review.
Cited by
-
Uncertainty estimation for temperature measurement with diagnostic ultrasound.J Ther Ultrasound. 2016 Dec 1;4:28. doi: 10.1186/s40349-016-0071-x. eCollection 2016. J Ther Ultrasound. 2016. PMID: 27957332 Free PMC article.
-
Thermometry and ablation monitoring with ultrasound.Int J Hyperthermia. 2015 Mar;31(2):163-81. doi: 10.3109/02656736.2015.1009180. Epub 2015 Mar 10. Int J Hyperthermia. 2015. PMID: 25753369 Free PMC article. Review.
-
Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.Med Biol Eng Comput. 2016 Jun;54(6):967-81. doi: 10.1007/s11517-016-1480-2. Epub 2016 Apr 2. Med Biol Eng Comput. 2016. PMID: 27039402
-
Possible patient early diagnosis by ultrasonic noninvasive estimation of thermal gradients into tissues based on spectral changes modeling.Comput Math Methods Med. 2012;2012:275405. doi: 10.1155/2012/275405. Epub 2012 May 13. Comput Math Methods Med. 2012. PMID: 22654958 Free PMC article.
-
A new high-resolution spectral approach to noninvasively evaluate wall deformations in arteries.Comput Math Methods Med. 2014;2014:606202. doi: 10.1155/2014/606202. Epub 2014 Feb 13. Comput Math Methods Med. 2014. PMID: 24688596 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous