. 2009 Jan 19;632(1):128-34.
doi: 10.1016/j.aca.2008.10.061. Epub 2008 Nov 5.

Simultaneous detection for three kinds of veterinary drugs: chloramphenicol, clenbuterol and 17-beta-estradiol by high-throughput suspension array technology

Affiliations

Simultaneous detection for three kinds of veterinary drugs: chloramphenicol, clenbuterol and 17-beta-estradiol by high-throughput suspension array technology

Nan Liu et al. Anal Chim Acta. .

Abstract

Suspension array technology for simultaneous detection of three kinds of veterinary drugs, chloramphenicol (CAP), clenbuterol and 17-beta-estradiol has been developed. Conjugates of chloramphenicol and clenbuterol coupled with bovine serum albumin were synthesized and purified. Probes of suspension array were constituted by coupling the three conjugates on the fluorescent microspheres/beads and the microstructures of the beads' surface were observed by scanning electron microscopy which was a direct confirmation for the successful conjugates' coupling. The optimal addition of conjugates and the amounts of antibodies were optimized and selected, respectively. Standard curves were plotted and the coefficient of determination-R(2) was greater than 0.989 which suggested good logistic correlation. The detection ranges for the three veterinary drugs are 40-6.25x10(5) ng L(-1), 50-7.81x10(5) ng L(-1) and 1x10(3-)7.29x10(5) ng L(-1), respectively and the lowest detection limits (LDLs) of them are 40, 50 and 1000 ng L(-1), respectively. The suspension array is specific and has no significant cross-reactivity with other chemicals. Meanwhile, unknown samples were detected by suspension array and ELISA in comparison with each other. The errors between found and real for the detection of the unknown samples were relatively small to both of the two methods, whereas, the detection ranges of suspension array are broader and sensitive than that of the traditional ELISA. The high-throughput suspension array is proved to be a novel method for multi-analysis of veterinary drugs with simple operation, high sensitivity and low cost.