. 2009 Jan;35(1):70-5.
doi: 10.1016/j.jcrs.2008.09.027.

Prevalence of corneal astigmatism before cataract surgery

Affiliations

Prevalence of corneal astigmatism before cataract surgery

Teresa Ferrer-Blasco et al. J Cataract Refract Surg. 2009 Jan.

Abstract

Purpose: To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.

Setting: University of Valencia, Valencia, Spain.

Methods: Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.

Results: Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in older groups (Kruskal-Wallis, P<.01). In 13.2% of eyes, no corneal astigmatism was present; in 64.4%, corneal astigmatism was between 0.25 and 1.25 diopters (D) and in 22.2%, it was 1.50 D or higher.

Conclusions: Corneal astigmatism less than 1.25 D was present in most cataract surgery candidates; it was higher in about 22%, with slight differences between the various age ranges. This information is useful for intraocular lens (IOL) manufacturers to evaluate which age ranges concentrate the parameters most frequently needed in sphere and cylinder powers and for surgeons to evaluate which IOLs provide the most effective power range.

PubMed Disclaimer

Comment in

  • Corneal cylinder in cataractous eyes.
    Hoffer KJ. Hoffer KJ. J Cataract Refract Surg. 2009 Jun;35(6):958; author reply 958-9. doi: 10.1016/j.jcrs.2009.01.047. J Cataract Refract Surg. 2009. PMID: 19465257 No abstract available.

Publication types