Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Dec;184(12):668-73.
doi: 10.1007/s00066-008-1875-6. Epub 2008 Dec 24.

Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

Affiliations
Comparative Study

Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

Buelent Polat et al. Strahlenther Onkol. 2008 Dec.

Abstract

Purpose: To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer.

Patients and methods: During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed.

Results: With a median treatment time of 16 min, intra-fractional drifts of the prostate were >5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R2=0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R2=0.55).

Conclusion: Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction.

PubMed Disclaimer

References

    1. Int J Radiat Oncol Biol Phys. 2007 Oct 1;69(2):419-25 - PubMed
    1. Int J Radiat Oncol Biol Phys. 2002 Aug 1;53(5):1097-105 - PubMed
    1. Int J Radiat Oncol Biol Phys. 1984 Mar;10(3):401-9 - PubMed
    1. Int J Radiat Oncol Biol Phys. 1999 Jun 1;44(3):525-33 - PubMed
    1. Strahlenther Onkol. 2007 Nov;183(11):617-24 - PubMed

LinkOut - more resources