Exploring blocking assays using Octet, ProteOn, and Biacore biosensors
- PMID: 19111520
- DOI: 10.1016/j.ab.2008.11.038
Exploring blocking assays using Octet, ProteOn, and Biacore biosensors
Abstract
We demonstrate the use of label-free real-time optical biosensors in competitive binding assays by epitope binning a panel of antibodies. We describe three assay orientations that we term in tandem, premix, and classical sandwich blocking, and we perform each of them on three platforms: ForteBio's Octet QK, Bio-Rad's ProteOn XPR36, and GE Healthcare's Biacore 3000. By testing whether antibodies block one another's binding to their antigen in a pairwise fashion, we establish a blocking profile for each antibody relative to the others in the panel. The blocking information is then used to create "bins" of antibodies with similar epitopes. The advantages and disadvantages of each biosensor, factors to consider when deciding on the most appropriate blocking assay orientation for a particular interaction system, and tips for dealing with ambiguous data are discussed. The data from our different assay orientations and biosensors agree very well, establishing these machines as valuable tools for characterizing antibody epitopes and multiprotein complexes of biological significance.
Similar articles
-
Determining kinetics and affinities of protein interactions using a parallel real-time label-free biosensor, the Octet.Anal Biochem. 2008 Jun 15;377(2):209-17. doi: 10.1016/j.ab.2008.03.035. Epub 2008 Mar 25. Anal Biochem. 2008. PMID: 18405656
-
Comparison of biosensor platforms in the evaluation of high affinity antibody-antigen binding kinetics.Anal Biochem. 2016 Sep 1;508:78-96. doi: 10.1016/j.ab.2016.06.024. Epub 2016 Jun 27. Anal Biochem. 2016. PMID: 27365220
-
Expanding the ProteOn XPR36 biosensor into a 36-ligand array expedites protein interaction analysis.Anal Biochem. 2011 Apr 1;411(1):139-51. doi: 10.1016/j.ab.2010.12.020. Epub 2010 Dec 17. Anal Biochem. 2011. PMID: 21168382
-
The use of biosensor technology for the engineering of antibodies and enzymes.J Mol Recognit. 1999 May-Jun;12(3):198-216. doi: 10.1002/(SICI)1099-1352(199905/06)12:3<198::AID-JMR458>3.0.CO;2-9. J Mol Recognit. 1999. PMID: 10398410 Review.
-
Optical biosensors: where next and how soon?Drug Discov Today. 2006 Dec;11(23-24):1061-7. doi: 10.1016/j.drudis.2006.10.003. Epub 2006 Oct 19. Drug Discov Today. 2006. PMID: 17129824 Review.
Cited by
-
Antibodies Targeting Closely Adjacent or Minimally Overlapping Epitopes Can Displace One Another.PLoS One. 2017 Jan 6;12(1):e0169535. doi: 10.1371/journal.pone.0169535. eCollection 2017. PLoS One. 2017. PMID: 28060885 Free PMC article.
-
Determination of High-affinity Antibody-antigen Binding Kinetics Using Four Biosensor Platforms.J Vis Exp. 2017 Apr 17;(122):55659. doi: 10.3791/55659. J Vis Exp. 2017. PMID: 28448040 Free PMC article.
-
Discovery and characterization of potent IL-21 neutralizing antibodies via a novel alternating antigen immunization and humanization strategy.PLoS One. 2019 Jan 25;14(1):e0211236. doi: 10.1371/journal.pone.0211236. eCollection 2019. PLoS One. 2019. PMID: 30682117 Free PMC article.
-
Facile generation of biepitopic antibodies with intrinsic agonism for activating receptors in the tumor necrosis factor superfamily.bioRxiv [Preprint]. 2023 Dec 12:2023.12.11.571146. doi: 10.1101/2023.12.11.571146. bioRxiv. 2023. Update in: Cell Chem Biol. 2024 May 16;31(5):944-954.e5. doi: 10.1016/j.chembiol.2024.03.010. PMID: 38168220 Free PMC article. Updated. Preprint.
-
Generation of Thermally Stable Affinity Pairs for Sensitive, Specific Immunoassays.Methods Mol Biol. 2022;2491:417-469. doi: 10.1007/978-1-0716-2285-8_21. Methods Mol Biol. 2022. PMID: 35482202
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources