Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances
- PMID: 19121502
- DOI: 10.1016/j.ajodo.2006.12.018
Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances
Abstract
Introduction: The purpose of this study was to examine whether nickel-titanium (Ni-Ti) archwires cause an increase of nickel concentration in the saliva of 18 orthodontic patients to estimate the possible risk of these archwires in patients who have nickel hypersensitivity.
Methods: Saliva samples were collected before orthodontic treatment, after placement of the bands and brackets, 2 weeks later and before placing the Ni-Ti archwires, immediately after placing the Ni-Ti archwires, 4 weeks after placing the wires, and 8 weeks after placing the wires.
Results: By using mass spectrometry, no statistically significant differences were found in the nickel concentrations in the samples taken without appliances, in those obtained 2 weeks after placement of the bands and brackets, and 4 and 8 weeks after placement of the archwires. Samples taken immediately after placement of the bands and brackets and the Ni-Ti archwires showed slight but significant increases in nickel concentration of 78 and 56 microg per liter, respectively, compared with the pretreatment value of 34 microg per liter.
Conclusions: Nickel leaching occurred after placement of the bands and brackets and after placement of the Ni-Ti archwires, associated with an increase of the nickel ion concentration in the patient's saliva. This effect decreased within 10 weeks.
Similar articles
-
Corrosion susceptibility and nickel release of nickel titanium wires during clinical application.J Orofac Orthop. 2008 Nov;69(6):411-23. doi: 10.1007/s00056-008-0808-4. Epub 2008 Nov 11. J Orofac Orthop. 2008. PMID: 19169638 English, German.
-
In vitro surface corrosion of stainless steel and NiTi orthodontic appliances.Aust Orthod J. 2003 Apr;19(1):13-8. Aust Orthod J. 2003. PMID: 12790351
-
Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.Am J Orthod Dentofacial Orthop. 2005 Jun;127(6):662-9. doi: 10.1016/j.ajodo.2005.01.015. Am J Orthod Dentofacial Orthop. 2005. PMID: 15953890
-
In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.Angle Orthod. 2002 Jun;72(3):222-37. doi: 10.1043/0003-3219(2002)072<0222:IVAOOA>2.0.CO;2. Angle Orthod. 2002. PMID: 12071606 Review.
-
Deformation of orthodontic archwires over time.Aust Orthod J. 1994 Oct;13(3):152-8. Aust Orthod J. 1994. PMID: 8975645 Review.
Cited by
-
A comparative study of bio degradation of various orthodontic arch wires: an in vitro study.J Int Oral Health. 2015 Jan;7(1):12-7. J Int Oral Health. 2015. PMID: 25709360 Free PMC article.
-
Surface characterization of passive film and elemental release analysis of a Ni-Cr alloy during bleaching, part I: effects of different bleaching agents.Clin Oral Investig. 2011 Jun;15(3):375-82. doi: 10.1007/s00784-010-0391-0. Epub 2010 Mar 9. Clin Oral Investig. 2011. PMID: 20217160
-
Bacterial Exposure to Nickel: Influence on Adhesion and Biofilm Formation on Orthodontic Archwires and Sensitivity to Antimicrobial Agents.Materials (Basel). 2021 Aug 16;14(16):4603. doi: 10.3390/ma14164603. Materials (Basel). 2021. PMID: 34443123 Free PMC article.
-
Metal release profiles of orthodontic bands, brackets, and wires: an in vitro study.J Orofac Orthop. 2017 Nov;78(6):494-503. doi: 10.1007/s00056-017-0107-z. Epub 2017 Sep 14. J Orofac Orthop. 2017. PMID: 28913542 Free PMC article.
-
A Comparative Study of Biodegradation of Nickel and Chromium from Space Maintainers: An in vitro Study.Int J Clin Pediatr Dent. 2015 Jan-Apr;8(1):37-41. doi: 10.5005/jp-journals-10005-1280. Epub 2015 Apr 28. Int J Clin Pediatr Dent. 2015. PMID: 26124579 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources