. 2009 Jan;79(1):150-7.
doi: 10.2319/122407-599.1.

Linear accuracy of cone beam CT derived 3D images

Affiliations
Free article

Linear accuracy of cone beam CT derived 3D images

April A Brown et al. Angle Orthod. 2009 Jan.
Free article

Abstract

Objective: To compare the in vitro reliability and accuracy of linear measurements between cephalometric landmarks on cone beam computed tomography (CBCT) 3D volumetric images with varying basis projection images to direct measurements on human skulls.

Materials and methods: Sixteen linear dimensions between 24 anatomic sites marked on 19 human skulls were directly measured. The skulls were imaged with CBCT (i-CAT, Imaging Sciences International, Hatfield, Pa) at three settings: (a) 153 projections, (b) 306 projections, and (c) 612 projections. The mean absolute error and modality mean (+/- SD) of linear measurements between landmarks on volumetric renderings were compared to the anatomic truth using repeated measures general linear model (P < or = .05).

Results: No difference in mean absolute error between the scan settings was found for almost all measurements. The average skull absolute error between marked reference points was less than the distances between unmarked reference sites. CBCT resulted in lower measurements for nine dimensions (mean difference range: 3.1 mm +/- 0.12 mm to 0.56 mm +/- 0.07 mm) and a greater measurement for one dimension (mean difference 3.3 mm +/- 0.12 mm). No differences were detected between CBCT scan sequences.

Conclusions: CBCT measurements were consistent between scan sequences and for direct measurements between marked reference points. Reducing the number of projections for 3D reconstruction did not lead to reduced dimensional accuracy and potentially provides reduced patient radiation exposure. Because the fiducial landmarks on the skulls were not radio-opaque, the inaccuracies found in measurement could be due to the methods applied rather than to innate inaccuracies in the CBCT scan reconstructions or 3D software employed.