Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2009 May;45(8):1389-96.
doi: 10.1016/j.ejca.2008.11.043. Epub 2009 Jan 3.

Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a systematic review and meta-analysis

Ping Gu et al. Eur J Cancer. 2009 May.

Abstract

Study objectives: Recently, less invasive methods have emerged as potential alternatives for staging with tissue confirmation of suspected metastatic mediastinal lymph nodes in lung cancer. The objective of this review was to assess the overall diagnostic accuracy of EBUS-TBNA in detecting metastatic mediastinal lymph node in lung cancer with a meta-analysis.

Methods: The MEDLINE, EMBASE, Cancerlit and Cochrane Library database, from January 1995 to September 2008, were searched for studies evaluating EBUS-TBNA accuracy. Meta-analysis methods were used to pool sensitivity and specificity and to construct summary receiver-operating characteristic.

Results: A total of 11 studies with 1299 patients, who fulfilled all of the inclusion criteria, were considered for the analysis. No publication bias was found. EBUS-TBNA had a pooled sensitivity of 0.93 (95% CI, 0.91-0.94) and a pooled specificity of 1.00 (95% CI, 0.99-1.00). The subgroup of patients who were selected on the basis of CT or PET positive results had higher pooled sensitivity (0.94, 95% CI 0.93-0.96) than the subgroup of patients without any selection of CT or PET (0.76, 95% CI 0.65-0.85) (p<0.05). Study sensitivity was not correlated with the prevalence of lymph node metastasis. Only two complications occurred (0.15%).

Conclusion: EBUS-TBNA was an accurate, safe and cost-effective tool in lung cancer staging. The selection of patients who had positive results of suspected lymph node metastasis in CT or PET may improve the sensitivity of EBUS-TBNA. High-quality prospective studies regarding EBUS-TBNA in lung cancer staging are still needed to be conducted.

PubMed Disclaimer

LinkOut - more resources