Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2009 Mar;37(3):198-203.
doi: 10.1016/j.jdent.2008.11.011. Epub 2009 Jan 7.

A prospective randomized clinical trial of one bis-GMA-based and two ormocer-based composite restorative systems in class II cavities: Five-year results

Affiliations
Randomized Controlled Trial

A prospective randomized clinical trial of one bis-GMA-based and two ormocer-based composite restorative systems in class II cavities: Five-year results

P Bottenberg et al. J Dent. 2009 Mar.

Abstract

Objectives: Ormocer composites, consisting of a silicon-based polymer, have been developed recently as a tooth-colored restorative material. The purpose of this prospective randomized clinical trial was to evaluate the performance of two small-particle hybrid ormocer-based restorative systems (AD, Admira/Admira Bond, VOCO; DE, Definite/Etch & Prime 3.0, Dentsply) and one small-particle hybrid bis-GMA-based composite restorative system (TC, Tetric-Ceram/Syntac, Ivoclar-Vivadent) in class II cavities.

Methods: From 128 occlusal-proximal restorations (44 AD, 43 DE and 41 TC) placed in 32 adult patients, eventually 77 (22 AD, 29 DE and 26 TC) remained available for evaluation after 5 years. Their clinical performance was scored according to the USPHS criteria and evaluation of bite-wing radiographs.

Results: After 5 years, eight AD, six DE and seven TC restorations had failed (p=0.10, log-rank test). The main reason was fracture or marginal gap formation, while secondary caries accounted for four failures. In all restorations the quality of surface, margins and contact point decreased significantly compared to baseline. DE had a significant poorer color match (p<0.01). Statistical evaluation using the KW test showed that failures were concentrated on specific patients.

Conclusions: In a group of class II restorations, there was no significant difference in failures after 5 years between ormocer-based and bis-GMA-based restorative systems.

PubMed Disclaimer

Publication types

LinkOut - more resources