Randomized Controlled Trial
. 2008 Dec;5(5):641-7.
doi: 10.1111/j.1742-481X.2007.00407.x.

Definition of efficiency in vacuum therapy--a randomised controlled trial comparing with V.A.C. Therapy

Affiliations
Randomized Controlled Trial

Definition of efficiency in vacuum therapy--a randomised controlled trial comparing with V.A.C. Therapy

Thomas Wild et al. Int Wound J. 2008 Dec.

Abstract

Redon drains are still used to suction wounds for vacuum sealing. Vacuum-assisted closure (V.A.C.((R)); Kinetic Concepts Inc, San Antonio, TX) is a computer-controlled therapy system for delivering topical negative pressure therapy. The efficiency of V.A.C. in the treatment of pressure ulcers was prospectively studied in a randomised controlled trial in which patients with pressure ulcers were randomly assigned to negative pressure wound therapy (NPWT) using either V.A.C. or Redon bottles. The target parameters were absolute and relative proportion of wound area consists of granulation tissue, fibrin and necrosis. Other outcome measures were the number of dressing changes and time invested using each system. The study was terminated after a post hoc analysis after inclusion of ten patients because of the significantly better results when using V.A.C., and the substantially larger care effort needed in the Redon group compared with the V.A.C. group. An increase in surface granulation tissue of 54% was observed in the V.A.C. group, and a reduction in the Redon group (P = 0.001). The Redon group showed an increase in fibrin tissue at the wound base of 21.8%, whereas in the V.A.C group, a 27% reduction was observed (P = 0.035). Necrosis was reduced in the V.A.C. group, but this difference did not reach significance. Redon bottles are not a good alternative for V.A.C. therapy for delivering NPWT.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Typical Redon bottle serving as vacuum source for delivering negative pressure wound therapy.
Figure 2
Figure 2
(A) V.A.C. – Tissue in percentage. Day 1: Necrosectomy and start of the treatment. Day 2: After 1 day of the therapy. Last day: 8–9 days of treatment. (B) Redon – Tissue in percentage. Day 1: Necrosectomy and start of the treatment. Day 2: After 1 day of the therapy. Last day: 8–9 days of treatment.

References

    1. Argenta LC, Morykwas MJ. Vacuum‐assisted closure: a new method for wound control and treatment: clinical experience. Ann Plast Surg 1997;38:563–76. - PubMed
    1. Morykwas MJ, Argenta LC, Shelton‐Brown EI, McGuirt W. Vacuum‐assisted closure: a new method for wound control and treatment: animal studies and basic foundation. Ann Plast Surg 1997;38:553–62. - PubMed
    1. Fleischmann W, Becker U, Bischoff M, Hoekstra H. Vacuum sealing: indication, technique and results. Zentralbl Chir 2006;131:68–71. - PubMed
    1. Timmers MS, Le CS, Banwell P, Jukema GN. The effects of varying degrees of pressure delivered by negative‐pressure wound therapy on skin perfusion. Ann Plast Surg 2005;55:665–71. - PubMed
    1. Greene AK. Microdeformational wound therapy: effects on angiogenesis and matrix metalloproteinases in chronic wounds of 3 debilitated patients. Ann Plast Surg 2006;56:418–22. - PubMed

Publication types

MeSH terms