3-Carboxy-6-chloro-7-hydroxycoumarin: a highly fluorescent, water-soluble violet-excitable dye for cell analysis
- PMID: 19135024
- DOI: 10.1016/j.ab.2008.12.018
3-Carboxy-6-chloro-7-hydroxycoumarin: a highly fluorescent, water-soluble violet-excitable dye for cell analysis
Abstract
In our search for new violet-excitable dyes with improved photophysical and photochemical properties, we examined several halogen-substituted hydroxycoumarins and found that chlorinated derivatives are at least as bright as their fluorinated analogs. A monochlorinated hydroxycoumarin was found to have a high quantum yield (approximately 0.98), and human leucocyte-specific monoclonal antibodies (CD3, CD4, and CD45) conjugated with this dye exhibited reliable performance in flow cytometry assays. Additional studies were performed, with BD Horizon V450-antibody conjugates being included in eight-color cocktails aimed at subsetting lymphocytes and myeloid cells. Such cocktails can frequently be unstable due to the tendency of one or more components to lose structural integrity, photobleach, or develop unwanted affinities for another component. However, the cocktails employed in this study enabled several different applications to be run and established that multicolor reagent mixtures containing V450-antibody conjugates are functional and stable.
Similar articles
-
New violet-excitable reagents for multicolor flow applications.Cytometry A. 2013 Aug;83(8):752-62. doi: 10.1002/cyto.a.22309. Epub 2013 Jun 13. Cytometry A. 2013. PMID: 23765858
-
Quantum dots in flow cytometry.Methods Mol Biol. 2007;374:185-203. doi: 10.1385/1-59745-369-2:185. Methods Mol Biol. 2007. PMID: 17237540
-
The new violet laser dye, Krome Orange, allows an optimal polychromatic immunophenotyping based on CD45-KO gating.J Immunol Methods. 2011 Sep 30;372(1-2):42-51. doi: 10.1016/j.jim.2011.06.025. Epub 2011 Jul 14. J Immunol Methods. 2011. PMID: 21781971
-
Hyperchromatic cytometry principles for cytomics using slide based cytometry.Cytometry A. 2006 Jul;69(7):691-703. doi: 10.1002/cyto.a.20285. Cytometry A. 2006. PMID: 16680709 Review.
-
Considerations for the control of background fluorescence in clinical flow cytometry.Cytometry B Clin Cytom. 2009 Nov;76(6):355-64. doi: 10.1002/cyto.b.20485. Cytometry B Clin Cytom. 2009. PMID: 19575390 Review.
Cited by
-
Synthesis of Monofluorinated 7-Hydroxycoumarin-3-Carboxamides as Cell-Permeable Fluorescent Molecular Probes.ACS Med Chem Lett. 2024 Apr 15;15(5):677-683. doi: 10.1021/acsmedchemlett.4c00085. eCollection 2024 May 9. ACS Med Chem Lett. 2024. PMID: 38746887 Free PMC article.
-
EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols.Leukemia. 2012 Sep;26(9):1986-2010. doi: 10.1038/leu.2012.122. Leukemia. 2012. PMID: 22948490 Free PMC article. Review.
-
Synthesis and evaluation of self-calibrating ratiometric viscosity sensors.Org Biomol Chem. 2011 May 7;9(9):3530-40. doi: 10.1039/c0ob01042a. Epub 2011 Mar 24. Org Biomol Chem. 2011. PMID: 21437318 Free PMC article.
-
Coumarin-Synthetic Methodologies, Pharmacology, and Application as Natural Fluorophore.Top Curr Chem (Cham). 2024 May 9;382(2):16. doi: 10.1007/s41061-024-00462-z. Top Curr Chem (Cham). 2024. PMID: 38722386 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous