Comparison of SPM and NEUROSTAT in voxelwise statistical analysis of brain SPECT and MRI at the early stage of Alzheimer's disease
- PMID: 19142712
- DOI: 10.1007/s12149-008-0211-7
Comparison of SPM and NEUROSTAT in voxelwise statistical analysis of brain SPECT and MRI at the early stage of Alzheimer's disease
Abstract
Objective: Neuroimaging plays a major role in the early diagnosis of Alzheimer's disease (AD). Recent advances in voxelwise statistical analysis after anatomic standardization of images have made this early diagnosis easier and more objective than visual inspection. We present comparative observations of NEUROSTAT, statistical parametric mapping (SPM) 99, and SPM2 in the early diagnosis of AD using brain perfusion single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI).
Methods: We performed voxel-by-voxel statistical group analysis for brain perfusion SPECT and gray matter images segmented from MRI between 61 patients with very early AD and 82 age-matched healthy volunteers. Anatomic standardization was performed using NEUROSTAT, SPM99, and SPM2 using both original and common templates.
Results: The location of significant reduction of regional cerebral blood flow (rCBF) for SPECT and gray matter concentration for MRI were identical among these three methods irrespective of the templates used. When using the original template, the significance of peak rCBF reduction in the posterior cingulate gyri was higher in SPM99 and SPM2 than that in NEUROSTAT. On the other hand, when using the common template, the significance of peak rCBF reduction in the posterior cingulate gyri was higher in NEUROSTAT and SPM2 than that in SPM99. NEUROSTAT showed almost the equal significance of peak rCBF reduction between the used templates. Almost the equal significance of reduction in gray matter concentration was observed in the parahippocampal gyri among the three methods.
Conclusions: NEUROSTAT, SPM99, and SPM2 showed identical location of significant reductions in rCBF and gray matter concentration in very early AD patients. Used templates for anatomic standardization are relevant to the results of voxelwise statistical analysis in SPM, less prominently in SPM2 than in SPM99, whereas irrelevant in NEUROSTAT.
Similar articles
-
Superiority of 3-dimensional stereotactic surface projection analysis over visual inspection in discrimination of patients with very early Alzheimer's disease from controls using brain perfusion SPECT.J Nucl Med. 2004 Sep;45(9):1450-7. J Nucl Med. 2004. PMID: 15347711 Clinical Trial.
-
Statistical brain mapping of 18F-FDG PET in Alzheimer's disease: validation of anatomic standardization for atrophied brains.J Nucl Med. 2001 Apr;42(4):548-57. J Nucl Med. 2001. PMID: 11337540
-
Functional interactions between entorhinal cortex and posterior cingulate cortex at the very early stage of Alzheimer's disease using brain perfusion single-photon emission computed tomography.Nucl Med Commun. 2006 Feb;27(2):151-6. doi: 10.1097/01.mnm.0000189783.39411.ef. Nucl Med Commun. 2006. PMID: 16404228
-
Functional neuroimaging in Alzheimer's disease.Radiat Med. 2006 May;24(4):302-8. doi: 10.1007/s11604-006-2408-9. Radiat Med. 2006. PMID: 16958406 Review. No abstract available.
-
The role of neuroimaging in dementia.Clin Geriatr Med. 2001 May;17(2):255-79. doi: 10.1016/s0749-0690(05)70068-9. Clin Geriatr Med. 2001. PMID: 11375135 Review.
Cited by
-
Structural and functional brain changes in perimenopausal women who are susceptible to migraine: a study protocol of multi-modal MRI trial.BMC Med Imaging. 2018 Sep 6;18(1):26. doi: 10.1186/s12880-018-0272-6. BMC Med Imaging. 2018. PMID: 30189858 Free PMC article. Clinical Trial.
-
Comparative Study of Voxel-Based Epileptic Foci Localization Accuracy between Statistical Parametric Mapping and Three-dimensional Stereotactic Surface Projection.Front Neurol. 2016 Sep 27;7:164. doi: 10.3389/fneur.2016.00164. eCollection 2016. Front Neurol. 2016. PMID: 27729898 Free PMC article.
-
Impact of injected dose and acquisition time on a normal database by use of 3D-SSP in SPECT images: quantitative simulation studies.Radiol Phys Technol. 2015 Jul;8(2):224-31. doi: 10.1007/s12194-015-0311-8. Epub 2015 Mar 11. Radiol Phys Technol. 2015. PMID: 25758210
-
Reduced Hypoxic Tissue and Cognitive Improvement after Revascularization Surgery for Chronic Cerebral Ischemia.Cerebrovasc Dis. 2019;47(1-2):57-64. doi: 10.1159/000497244. Epub 2019 Feb 15. Cerebrovasc Dis. 2019. PMID: 30783065 Free PMC article.
-
Does preoperative measurement of cerebral blood flow with acetazolamide challenge in addition to preoperative measurement of cerebral blood flow at the resting state increase the predictive accuracy of development of cerebral hyperperfusion after carotid endarterectomy? Results from 500 cases with brain perfusion single-photon emission computed tomography study.Neurol Med Chir (Tokyo). 2015;55(2):141-8. doi: 10.2176/nmc.oa.2014-0269. Epub 2015 Jan 23. Neurol Med Chir (Tokyo). 2015. PMID: 25746308 Free PMC article.