Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2009 Feb;64(2):195-8.
doi: 10.1111/j.1365-2044.2008.05735.x.

Pumpless extracorporeal removal of carbon dioxide combined with ventilation using low tidal volume and high positive end-expiratory pressure in a patient with severe acute respiratory distress syndrome

Affiliations
Free article
Case Reports

Pumpless extracorporeal removal of carbon dioxide combined with ventilation using low tidal volume and high positive end-expiratory pressure in a patient with severe acute respiratory distress syndrome

T Bein et al. Anaesthesia. 2009 Feb.
Free article

Abstract

The effects of the combination of a 'lowest' lung ventilation with extracorporeal elimination of carbon dioxide by interventional lung assist are described in a patient presenting with severe acute respiratory distress syndrome due to fulminant pneumonia. Reducing tidal volume to 3 ml.kg(-1) together with interventional lung assist resulted in a decrease in severe hypercapnia without alveolar collapse or hypoxaemia but with a decrease in serum levels of interleukin-6. This approach was applied for 12 days with recovery of the patient, without complications. Extracorporeal removal of carbon dioxide by interventional lung assist may be a useful tool to enable 'ultraprotective' ventilation in severe acute respiratory distress syndrome.

PubMed Disclaimer

Publication types

LinkOut - more resources