Development of up-converting phosphor technology-based lateral-flow assay for rapidly quantitative detection of hepatitis B surface antibody
- PMID: 19150709
- DOI: 10.1016/j.diagmicrobio.2008.10.020
Development of up-converting phosphor technology-based lateral-flow assay for rapidly quantitative detection of hepatitis B surface antibody
Abstract
An up-converting phosphor technology-based lateral-flow (UPT-LF) assay system was developed for rapid and quantitative detection of hepatitis B surface antibody (HBsAb). To evaluate its performance, we compared it with the Abbott Axsym AUSAB (ABBOTT Diagnostics Division, Wiesbaden, Germany) assay and conventional ELISA (Wantai Biological Pharmacy Enterprise, Beijing, China) using 13 standard positive sera and 306 clinical sera. In both laboratory evaluation and clinical application, UPT-LF assay showed the best sensitivity (99.19%) and detection agreement (97.43% for the adjusted agreement) with true results. The concordance rate between UPT-LF and ELISA, as shown by correlative regression analysis, was the highest (R(2)=0.6389), whereas that between UPT-LF and AUSAB was the lowest (R(2)=0.5702). In conclusion, UPT-LF assay for quantitative detection of HBsAb is sensitive and rapid, promising this new assay a bright future.
Similar articles
-
Development of an up-converting phosphor technology-based 10-channel lateral flow assay for profiling antibodies against Yersinia pestis.J Microbiol Methods. 2010 Nov;83(2):133-40. doi: 10.1016/j.mimet.2010.08.005. Epub 2010 Aug 27. J Microbiol Methods. 2010. PMID: 20801166
-
Rapid and quantitative detection of Brucella by up-converting phosphor technology-based lateral-flow assay.J Microbiol Methods. 2009 Oct;79(1):121-3. doi: 10.1016/j.mimet.2009.07.015. Epub 2009 Jul 25. J Microbiol Methods. 2009. PMID: 19635504
-
Surface acoustic wave immunosensor for real-time detection of hepatitis B surface antibodies in whole blood samples.Biosens Bioelectron. 2009 Jun 15;24(10):3120-5. doi: 10.1016/j.bios.2009.04.009. Epub 2009 Apr 17. Biosens Bioelectron. 2009. PMID: 19423329
-
Surface plasmon resonance biosensing.Methods Mol Biol. 2009;503:65-88. doi: 10.1007/978-1-60327-567-5_5. Methods Mol Biol. 2009. PMID: 19151937 Review.
-
Infrared up-converting phosphors for bioassays.IEE Proc Nanobiotechnol. 2005 Apr;152(2):64-72. doi: 10.1049/ip-nbt:20045014. IEE Proc Nanobiotechnol. 2005. PMID: 16441160 Review.
Cited by
-
Upconverting nanoparticle reporter-based highly sensitive rapid lateral flow immunoassay for hepatitis B virus surface antigen.Anal Bioanal Chem. 2021 Feb;413(4):967-978. doi: 10.1007/s00216-020-03055-z. Epub 2020 Nov 23. Anal Bioanal Chem. 2021. PMID: 33230700 Free PMC article.
-
Rapid and quantitative detection of Shiga toxin1 and Shiga toxin2 based on multiple targets UPT-LF assay.Eng Life Sci. 2020 Jul 19;20(11):494-503. doi: 10.1002/elsc.202000031. eCollection 2020 Nov. Eng Life Sci. 2020. PMID: 33204236 Free PMC article.
-
Lateral flow assay for simultaneous detection of cellular- and humoral immune responses.Clin Biochem. 2011 Oct;44(14-15):1241-6. doi: 10.1016/j.clinbiochem.2011.06.983. Epub 2011 Jul 6. Clin Biochem. 2011. PMID: 21763300 Free PMC article.
-
Lateral Flow Assay for Hepatitis B Detection: A Review of Current and New Assays.Micromachines (Basel). 2023 Jun 12;14(6):1239. doi: 10.3390/mi14061239. Micromachines (Basel). 2023. PMID: 37374824 Free PMC article. Review.
-
Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.Chem Rev. 2019 Jan 23;119(2):1456-1518. doi: 10.1021/acs.chemrev.8b00136. Epub 2018 Dec 4. Chem Rev. 2019. PMID: 30511833 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical