Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2009 Jan-Feb;16(1):113-21.
doi: 10.1007/s12350-008-9008-2. Epub 2009 Jan 20.

123I-mIBG scintigraphy to predict risk for adverse cardiac outcomes in heart failure patients: design of two prospective multicenter international trials

Affiliations
Clinical Trial

123I-mIBG scintigraphy to predict risk for adverse cardiac outcomes in heart failure patients: design of two prospective multicenter international trials

Arnold F Jacobson et al. J Nucl Cardiol. 2009 Jan-Feb.

Abstract

Background: ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) consists of two identical prospective open-label, multicenter, phase 3 studies (MBG311 and MBG312) evaluating the prognostic usefulness of (123)I-mIBG scintigraphy for identifying subjects with heart failure who will experience a major adverse cardiac event.

Methods: Subjects with NYHA class II and III heart failure and left ventricular ejection fraction < or = 35% were eligible for the trials. Subjects underwent planar and SPECT (123)I-mIBG myocardial imaging, as well as echocardiography and gated SPECT (99m)Tc-tetrofosmin myocardial perfusion imaging. Subjects are then monitored on a regular basis for 2 years. Time to first occurrence of one of the following--NYHA class progression; potentially life-threatening arrhythmic event (including ICD discharge); or cardiac death, as verified by an independent adjudication panel---will be analyzed in comparison to quantitative parameters derived from (123)I-mIBG imaging. The primary efficacy analysis will employ the heart/mediastinum ratio on 4-hour delayed planar imaging, while secondary efficacy analyses will examine quantitative results from both planar and SPECT (123)I-mIBG images, as well as from (99m)Tc-tetrofosmin SPECT and echocardiography.

Conclusion: The results of the ADMIRE-HF trials will provide prospective validation of the potential role of (123)I-mIBG scintigraphy in assessing prognosis and developing management strategies for patients with heart failure.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Heart. 1999 Feb;81(2):148-52 - PubMed
    1. N Engl J Med. 1982 Jul 22;307(4):205-11 - PubMed
    1. Kaku Igaku. 2001 Mar;38(2):99-104 - PubMed
    1. J Nucl Cardiol. 1998 Nov-Dec;5(6):579-90 - PubMed
    1. J Am Coll Cardiol. 1995 Jan;25(1):146-53 - PubMed

Publication types