Correlation between angiographic and particle image velocimetry quantifications of flow diverters in an in vitro model of elastase-induced rabbit aneurysms
- PMID: 19154077
- PMCID: PMC2679683
- DOI: 10.1115/1.3049528
Correlation between angiographic and particle image velocimetry quantifications of flow diverters in an in vitro model of elastase-induced rabbit aneurysms
Abstract
The rupture of a cerebral aneurysm can result in a hemorrhagic stroke. A flow diverter, which is a porous tubular mesh, can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. By finding a correlation between particle image velocimetry (PIV) and digital subtraction angiography, a better assessment of how well an aneurysm is excluded from the parent artery can be made in the clinical setting. A model of a rabbit elastase-induced aneurysm was connected to a mock circulation loop. The model was then placed under angiography. Recorded angiograms were analyzed so that a contrast concentration-time curve based on the average grayscale intensity inside the aneurysm could be determined. That curve was then fitted to a mathematical model that quantifies the influence of convection and diffusion on contrast transport. Optimized parameters were correlated with the intraneurysmal mean kinetic energy measured by PIV in the same aneurysm model. A strong correlation was observed between the convection and diffusion time constants and the mean kinetic energy inside the aneurysm. Analyzing the flow of angiographic contrast into and out of the aneurysm after implantation of a flow diverter allows for prediction of the efficacy of the device in excluding the aneurysm. Correlating hydrodynamic measures obtained by angiography to those obtained by detailed techniques such as PIV increases confidence in such predictions.
Figures



Similar articles
-
In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit.J Biomech Eng. 2007 Dec;129(6):863-72. doi: 10.1115/1.2800787. J Biomech Eng. 2007. PMID: 18067390
-
Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography.IEEE Trans Med Imaging. 2009 Jul;28(7):1117-25. doi: 10.1109/TMI.2008.2012162. Epub 2009 Jan 19. IEEE Trans Med Imaging. 2009. PMID: 19164085 Free PMC article.
-
Hemodynamics of Flow Diverters.J Biomech Eng. 2017 Feb 1;139(2). doi: 10.1115/1.4034932. J Biomech Eng. 2017. PMID: 27727400
-
Comparison of the in vitro hemodynamic performance of new flow diverters for bypass of brain aneurysms.J Biomech Eng. 2012 Aug;134(8):084505. doi: 10.1115/1.4006454. J Biomech Eng. 2012. PMID: 22938365 Free PMC article.
-
Angiographic assessment of the efficacy of flow diverter treatment for cerebral aneurysms.Interv Neuroradiol. 2019 Dec;25(6):655-663. doi: 10.1177/1591019919860829. Epub 2019 Jul 11. Interv Neuroradiol. 2019. PMID: 31296064 Free PMC article.
Cited by
-
Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis.Annu Rev Biomed Eng. 2020 Jun 4;22:231-256. doi: 10.1146/annurev-bioeng-092419-061429. Epub 2020 Mar 25. Annu Rev Biomed Eng. 2020. PMID: 32212833 Free PMC article. Review.
-
Parent artery reconstruction for large or giant cerebral aneurysms using a Tubridge flow diverter (PARAT): study protocol for a multicenter, randomized, controlled clinical trial.BMC Neurol. 2014 May 4;14:97. doi: 10.1186/1471-2377-14-97. BMC Neurol. 2014. PMID: 24885396 Free PMC article. Clinical Trial.
-
Risk factor analysis of changes in blood flow in the A1 segment of the anterior cerebral artery after flow-diverter coverage of it.Neurosurg Rev. 2024 Feb 5;47(1):74. doi: 10.1007/s10143-024-02306-2. Neurosurg Rev. 2024. PMID: 38315259
-
Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.PLoS One. 2014 Dec 3;9(12):e113762. doi: 10.1371/journal.pone.0113762. eCollection 2014. PLoS One. 2014. PMID: 25470724 Free PMC article.
-
Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results.AJNR Am J Neuroradiol. 2012 Sep;33(8):1436-46. doi: 10.3174/ajnr.A3246. Epub 2012 Jul 19. AJNR Am J Neuroradiol. 2012. PMID: 22821921 Free PMC article.
References
-
- American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Heart Disease and Stroke Statistics. Dallas, TX: American Heart Association; 2008.
-
- Marks MP, Dake MD, Steinberg GK, Norbash AM, Lane B. Stent placement for Arterial and Venous Cerebrovascular Disease: Preliminary Experience. Radiology. 1994;191:441–446. - PubMed
-
- Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN. Stents for Intracranial Aneurysms: The Beginning of a New Endovascular Era? Neurosurgery. 1998;43:377–379. - PubMed
-
- Miskolczi L, Guterman LR, Flaherty JD, Hopkins LN. Saccular Aneurysm Induction by Elastase Digestion of the Arterial Wall: A New Animal Model. Neurosurgery. 1998;43(3):595–600. - PubMed
-
- Cloft HJ, Altes TA, Marx WF, Raible RJ, Hudson SB, Helm GA, Mandell JW, Jensen ME, Dion JE, Kallmes DF. Endovascular Creation of an In Vivo Bifurcation Aneurysm Model in Rabbits. Radiology. 1999;213(1):223–228. - PubMed