Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
- PMID: 19154927
- DOI: 10.1016/j.jtcvs.2008.07.032
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
Abstract
Objective: Pulsatile and nonpulsatile left ventricular assist devices are effective in managing congestive heart failure. Despite early evidence for clinical efficacy, the long-term impact of nonpulsatile flow on end-organ function remains to be determined. Our goal was to compare rates of gastrointestinal bleeding in nonpulsatile and pulsatile device recipients.
Methods: In a retrospective review of 101 left ventricular assist device recipients (55 nonpulsatile, 46 pulsatile) from October 31, 2003, to June 1, 2007, at a single center, gastrointestinal bleeding was defined as guaiac-positive stool with hemoglobin drop requiring transfusion of at least 2 units of packed red blood cells. To assess bleeding risk outside the initial postoperative course, any patients with a device in place for 15 days or less was excluded.
Results: Twelve nonpulsatile and 3 pulsatile left ventricular assist device recipients had gastrointestinal bleeding 16 days or longer after device implantation. The event rates were 63 events/100 patient-years for nonpulsatile devices and 6.8 events/100 patient-years for pulsatile devices (P = .0004). This difference persisted for bleeding occurring 31 days or longer after device implantation, with 46.5 events/100 patient-years for nonpulsatile devices versus 4.7 events/100 patient-years for pulsatile devices (P = .0028). Mortalities were similar between groups (15% nonpulsatile vs 17% pulsatile, P = .6965).
Conclusion: Patients with nonpulsatile left ventricular assist devices appear to have a higher rate of gastrointestinal bleeding events than do pulsatile left ventricular assist device recipients. Further prospective evaluation is needed to determine potential etiologies and strategies for reducing gastrointestinal bleeding in this population.
Similar articles
-
Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients.Ann Thorac Surg. 2007 Mar;83(3):1082-8. doi: 10.1016/j.athoracsur.2006.10.034. Ann Thorac Surg. 2007. PMID: 17307463
-
Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.Ann Thorac Surg. 2008 Oct;86(4):1227-34; discussion 1234-5. doi: 10.1016/j.athoracsur.2008.06.030. Ann Thorac Surg. 2008. PMID: 18805167
-
Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.Ann Thorac Surg. 2008 Sep;86(3):832-40; discussion 832-40. doi: 10.1016/j.athoracsur.2008.05.016. Ann Thorac Surg. 2008. PMID: 18721570
-
Pulsatile vs. continuous flow in ventricular assist device therapy.Best Pract Res Clin Anaesthesiol. 2012 Jun;26(2):105-15. doi: 10.1016/j.bpa.2012.03.004. Best Pract Res Clin Anaesthesiol. 2012. PMID: 22910084 Review.
-
State of the art: implantable ventricular assist devices.Curr Opin Organ Transplant. 2009 Oct;14(5):554-9. doi: 10.1097/MOT.0b013e3283303750. Curr Opin Organ Transplant. 2009. PMID: 19667990 Review.
Cited by
-
Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.J Med Biol Eng. 2016;36:308-315. doi: 10.1007/s40846-016-0140-1. Epub 2016 Jun 25. J Med Biol Eng. 2016. PMID: 27441034 Free PMC article.
-
Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved?Heart Fail Rev. 2014 Mar;19(2):259-66. doi: 10.1007/s10741-013-9389-4. Heart Fail Rev. 2014. PMID: 23549998
-
Complications of Continuous-Flow Mechanical Circulatory Support Devices.Clin Med Insights Cardiol. 2015 May 21;9(Suppl 2):15-21. doi: 10.4137/CMC.S19708. eCollection 2015. Clin Med Insights Cardiol. 2015. PMID: 26052234 Free PMC article. Review.
-
Characteristics of gastrointestinal bleeding after placement of continuous-flow left ventricular assist device: a case series.Dig Dis Sci. 2015 Jun;60(6):1859-67. doi: 10.1007/s10620-015-3538-7. Epub 2015 Jan 24. Dig Dis Sci. 2015. PMID: 25616611
-
Mechanical circulatory support for advanced heart failure.Curr Treat Options Cardiovasc Med. 2010 Dec;12(6):549-65. doi: 10.1007/s11936-010-0093-6. Curr Treat Options Cardiovasc Med. 2010. PMID: 21063932
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical