Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Mar 15;115(6):1194-202.
doi: 10.1002/cncr.24154.

Accuracy of clinical evaluation of locally advanced breast cancer in patients receiving neoadjuvant chemotherapy

Affiliations
Comparative Study

Accuracy of clinical evaluation of locally advanced breast cancer in patients receiving neoadjuvant chemotherapy

Raquel Prati et al. Cancer. .

Abstract

Background: Physical examination (PE), mammography (MG), breast magnetic resonance imaging (MRI), fluorodeoxyglucose positron emission tomography (PET), and pathologic evaluation are used to assess primary breast cancer. To the authors' knowledge, their accuracy has not been well studied in patients receiving neoadjuvant chemotherapy. Accuracies of each modality in tumor and lymph node assessment in patients with T3/T4 tumors receiving neoadjuvant chemotherapy were compared.

Methods: Forty-five patients of a prospective clinical trial studying T3-T4M0 tumors were included. Patients received neoadjuvant chemotherapy: docetaxel/carboplatin with or without trastuzumab before and/or after surgery (depending on HER-2/neu status and randomization). Tumor measurements by PE, MG, and MRI and lymph node status by PE and PET were obtained before and after neoadjuvant chemotherapy. Concordance among different clinical measurements was assessed and compared with the tumor and lymph node staging by pathology. Spearman correlation (r) and root mean square error (RMSE) were used to measure the accuracy of measurements among all modalities and between modalities and pathologic tumor size.

Results: Compared with the tumor size measured by PE, MRI was more accurate than MG at baseline (r=0.559, RMSE=35.4% vs r=0.046, RMSE=66.1%). After neoadjuvant chemotherapy, PE correlated better with pathology than MG or MRI (r=0.655, RMSE=88.6% vs r=0.146, RMSE=147.1% and r=0.364, RMSE=92.6%). Axillary lymph node assessment after neoadjuvant chemotherapy demonstrated high specificity but low sensitivity by PET and PE.

Conclusions: Findings suggested that MRI was a more accurate imaging study at baseline for T3/T4 tumor, and PE correlated best with pathology finding. PET and PE both correctly predicted positive axillary lymph nodes but not negative lymph nodes.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Kaufman M, von Minckwitz G, Smith R, et al. International expert panel on the use of primary (preoperative) systemic treatment of operable breast cancer: review and recommendations. J Clin Oncol. 2003;21:2600–2608. - PubMed
    1. Londero V, Bazzocchi M, Del Frate C, et al. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy. Eur Radiol. 2004;14:1371–1379. - PubMed
    1. Rosen EL, Blackwell KL, Baker JA, et al. Accuracy of MRI in the detection of residual breast cancer after neoadjuvant chemotherapy. Am J Roentgenol. 2003;181:1275–1282. - PubMed
    1. Yeh E, Slanetz P, Kopans D. Prospective Comparison of Mammography, Sonography, and MRI in Patients Undergoing Neoadjuvant Chemotherapy for Palpable Breast Cancer. Am J Roentgenol. 2005;184:868–877. - PubMed
    1. Balu-Maestro C, Chapellier C, Bleuse A, et al. Imaging in evaluation of response to neoadjuvant breast cancer treatment benefits of MRI. Breast Cancer Res Treat. 2002;72:145–152. - PubMed

Publication types

MeSH terms

Substances