Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Mar 15;77(5):1680-7.
doi: 10.1016/j.talanta.2008.10.006. Epub 2008 Oct 17.

High-resolution surface plasmon resonance sensors based on a dove prism

Affiliations

High-resolution surface plasmon resonance sensors based on a dove prism

Olivier R Bolduc et al. Talanta. .

Abstract

Wavelength interrogation surface plasmon resonance (SPR) spectroscopy using a dove prism combines a simple and inexpensive optical design with high-resolution refractive index monitoring and biosensing. A BK7 dove prism inverts an optical image with a total internal reflection angle of 72.8 degrees , an angle active in SPR. Hence, a unique system can accomplish SPR biosensing using wavelength interrogation and also perform SPR imaging. This optical configuration advantageously uses a single axis optical path between each optical component, simplifying the optical design of SPR instruments without compromise of the analytical performance. Fluidics were also incorporated to the instrument design for efficient sample delivery. The SPR instrument is characterized in terms of refractive index (RI) sensitivity, RI resolution, reproducibility, and application for monitoring low concentration biological events. Data analysis methodologies are compared for improved resolution of the measured response. Raw data analyzed using a minimum hunting procedure results in RI resolution in the 10(-6) range, while pre-treating data with singular value decomposition improves the resolution by one order of magnitude. Depending on the spectrophotometer employed, the RI range accessible can be easily tuned; examples with a 550-850 nm and a 550-1100 nm spectrophotometers are shown and results respectively in RI ranges of 1.32-1.39 RIU and 1.32-1.42 RIU. Monitoring of microM concentration of beta-lactamase is performed using the wavelength interrogation configuration of the biosensor. Finally, a SPR image of a surface with a water droplet (volume=500 nL) was obtained using the dove prism SPR with a band pass filter and a CCD camera. SPR using a dove prism configuration combines advantages of portable SPR instruments, SPR imagers and research-grade SPR instruments in a unique platform.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources