Abstract
Background: Over the years, reticular prostheses have undergone changes in their structure and composition to give rise to today's partially absorbable lightweight meshes. This study was designed to assess the biological and biomechanical behavior of these prostheses to establish whether they offer any advantages over nonabsorbable lightweight polypropylene prostheses.
Materials and methods: 7 x 5 cm defects were created in the anterior abdominal wall of New Zealand White rabbits and repaired by securing different prostheses to the edges of the defect with a running 4/0 polypropylene suture. The lightweight biomaterials compared were two nonabsorbable meshes: Parietene and Optilene elastic, and two partially absorbable prostheses: Vypro II and Ultrapro. At 14 and 90 days postimplant, tissue/prosthesis specimens were subjected to histological, immunohistochemical, shrinkage, and biomechanical analyses.
Results: Adhesion formation on the peritoneum-facing surface of the meshes was significantly less extensive in the meshes with absorbable components at 90 days postimplant. The newly formed tissue around the prosthetic filaments was comprised of collagen fibers, fibroblasts, blood vessels, and macrophages. The partially absorbable meshes showed higher macrophage proportions (due to remnants of absorbable material and their structure) than the nonabsorbable meshes at 90 days, although differences were not significant. At 90 days postimplant, similar tensile strengths were recorded for all the implants.
Conclusions: All the prosthetic materials induced good host tissue ingrowth, with no significant differences in tensile strength observed. Our findings suggest that partially absorbable lightweight prostheses could offer advantages over nonabsorbable lightweight meshes since less foreign material persists in the recipient, improving abdominal wall compliance.
Similar articles
-
Partially absorbable meshes for hernia repair offer advantages over nonabsorbable meshes.Am J Surg. 2007 Jul;194(1):68-74. doi: 10.1016/j.amjsurg.2006.11.016. Am J Surg. 2007. PMID: 17560912
-
Comparing the behavior of different polypropylene meshes (heavy and lightweight) in an experimental model of ventral hernia repair.J Biomed Mater Res B Appl Biomater. 2009 May;89(2):448-455. doi: 10.1002/jbm.b.31234. J Biomed Mater Res B Appl Biomater. 2009. PMID: 18837449
-
Effect of relaparotomy through previously integrated polypropylene and polytetrafluoroethylene experimental implants in the abdominal wall.J Am Coll Surg. 1999 May;188(5):466-72. doi: 10.1016/s1072-7515(99)00029-0. J Am Coll Surg. 1999. PMID: 10235573
-
[Development of better tolerated prosthetic materials: applications in gynecological surgery].J Gynecol Obstet Biol Reprod (Paris). 2002 Oct;31(6):527-40. J Gynecol Obstet Biol Reprod (Paris). 2002. PMID: 12407323 Review. French.
-
[Role of the new lightweight prostheses in improving hernia repair].Cir Esp. 2009 May;85(5):268-73. doi: 10.1016/j.ciresp.2009.01.012. Epub 2009 Apr 22. Cir Esp. 2009. PMID: 19389663 Review. Spanish.
Cited by
-
The comparison of heavyweight mesh and lightweight mesh in an incisional animal model.Hernia. 2010 Aug;14(4):397-400. doi: 10.1007/s10029-010-0647-2. Epub 2010 Mar 13. Hernia. 2010. PMID: 20229105
-
Remodeling characteristics and collagen distribution in synthetic mesh materials explanted from human subjects after abdominal wall reconstruction: an analysis of remodeling characteristics by patient risk factors and surgical site classifications.Surg Endosc. 2014 Jun;28(6):1852-65. doi: 10.1007/s00464-013-3405-6. Epub 2014 Jan 18. Surg Endosc. 2014. PMID: 24442681 Free PMC article. Clinical Trial.
-
Combined use of composite mesh and acellular dermal matrix graft for abdominal wall repair following tumour resection.World J Surg Oncol. 2024 Aug 28;22(1):226. doi: 10.1186/s12957-024-03507-1. World J Surg Oncol. 2024. PMID: 39192281 Free PMC article.
-
Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair.Hernia. 2011 Aug;15(4):423-31. doi: 10.1007/s10029-011-0787-z. Epub 2011 Jan 30. Hernia. 2011. PMID: 21279663 Free PMC article.
-
BETWEEN PROLENE®, ULTRAPRO® AND BARD SOFT® MESHES WHICH PRESENTS THE BEST PERFORMANCE IN THE REPAIR OF THE ABDOMINAL WALL?Arq Bras Cir Dig. 2021 Jun 11;34(1):e1577. doi: 10.1590/0102-672020210001e1577. eCollection 2021. Arq Bras Cir Dig. 2021. PMID: 34133524 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources