A covariance-based algorithm: a novel technique for rhythm discrimination in ICDs
- PMID: 19163957
- DOI: 10.1109/IEMBS.2008.4650454
A covariance-based algorithm: a novel technique for rhythm discrimination in ICDs
Abstract
Inappropriate shocks due to misclassification of supraventricular and ventricular arrhythmias remain a major problem in the care of patients with Implantable Cardioverter defibrillators (ICDs). In this study we have investigated the ability of a new covariance-based algorithm, to distinguish Ventricular Tachycardia from other rhythms such as Supraventricular Tachycardia. The proposed algorithm has a low computational demand and with a small adjustment is applicable on both single-chamber and dual-chamber ICDs. The results are promising and suggest that the new covariance-based algorithm may be an effective method for ICD rhythm classification and may decrease inappropriate shocks.
Similar articles
-
A new approach for ICD rhythm classification based on support vector machines.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:2478-81. doi: 10.1109/IEMBS.2009.5334794. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964965
-
Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm.J Cardiovasc Electrophysiol. 2006 Dec;17(12):1310-9. doi: 10.1111/j.1540-8167.2006.00643.x. Epub 2006 Nov 10. J Cardiovasc Electrophysiol. 2006. PMID: 17096661 Clinical Trial.
-
Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO).Europace. 2009 Jun;11(6):727-33. doi: 10.1093/europace/eup099. Epub 2009 May 2. Europace. 2009. PMID: 19411676
-
Detection and discrimination of tachycardia in ICDs manufactured by St. Jude Medical.Herzschrittmacherther Elektrophysiol. 2016 Sep;27(3):226-39. doi: 10.1007/s00399-016-0455-1. Epub 2016 Sep 7. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27605236 Review. English.
-
Sensing and detection in Medtronic implantable cardioverter defibrillators.Herzschrittmacherther Elektrophysiol. 2016 Sep;27(3):193-212. doi: 10.1007/s00399-016-0450-6. Epub 2016 Sep 8. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27624809 Review. English.
Cited by
-
Inappropriate shocks in patients with ICDs: single chamber versus dual chamber.Arq Bras Cardiol. 2013 Aug;101(2):141-8. doi: 10.5935/abc.20130125. Epub 2013 Jul 2. Arq Bras Cardiol. 2013. PMID: 23821405 Free PMC article. Review.
-
Reduction of the inappropriate ICD therapies by implementing a new fuzzy logic-based diagnostic algorithm.Ann Noninvasive Electrocardiol. 2013 Sep;18(5):457-66. doi: 10.1111/anec.12090. Ann Noninvasive Electrocardiol. 2013. PMID: 24047490 Free PMC article.
MeSH terms
LinkOut - more resources
Medical