Comparison of the helical tomotherapy and MLC-based IMRT radiation modalities in treating brain and cranio-spinal tumors
- PMID: 19166237
- DOI: 10.1177/153303460900800102
Comparison of the helical tomotherapy and MLC-based IMRT radiation modalities in treating brain and cranio-spinal tumors
Abstract
The investigation of the clinical efficacy and effectiveness of Intensity Modulated Radiotherapy (IMRT) using Multileaf Collimators (MLC) and Helical Tomotherapy (HT) has been an issue of increasing interest over the past few years. In order to assess the suitability of a treatment plan, dosimetric criteria such as dose-volume histograms (DVH), maximum, minimum, mean, and standard deviation of the dose distribution are typically used. Nevertheless, the radiobiological parameters of the different tumors and normal tissues are often not taken into account. The use of the biologically effective uniform dose (D=) together with the complication-free tumor control probability (P(+)) were applied to evaluate the two radiation modalities. Two different clinical cases of brain and cranio-spinal axis cancers have been investigated by developing a linac MLC-based step-and-shoot IMRT plan and a Helical Tomotherapy plan. The treatment plans of the MLC-based IMRT were developed on the Philips treatment planning station using the Pinnacle 7.6 software release while the dedicated Tomotherapy treatment planning station was used for the HT plan. With the use of the P(+) index and the D(=) concept as the common prescription point, the different treatment plans were compared based on radiobiological measures. The tissue response probabilities were plotted against D(=) for a range of prescription doses. The applied plan evaluation method shows that in the brain cancer, the HT treatment gives slightly better results than the MLC-based IMRT in terms of optimum expected clinical outcome (P(+) of 66.1% and 63.5% for a D(=) to the PTV of 63.0 Gy and 62.0 Gy, respectively). In the cranio-spinal axis cancer, the HT plan is significantly better compared to the MLC-based IMRT plan over the clinically useful dose prescription range (P(+) of 84.1% and 28.3% for a D(=) to the PTV of 50.6 Gy and 44.0 Gy, respectively). If a higher than 5% risk for complications could be allowed, the complication-free tumor control could be increased by almost 30% compared to the initial dose prescription. In comparison to MLC based-IMRT, HT can better encompass the often large PTV while minimizing the volume of the OARs receiving high dose. A radiobiological treatment plan evaluation can provide a closer association of the delivered treatment with the clinical outcome by taking into account the dose-response relations of the irradiated tumors and normal tissues. The use of P - (D=) diagrams can complement the traditional tools of evaluation such as DVHs, in order to compare and effectively evaluate different treatment plans.
Similar articles
-
Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.Phys Med Biol. 2007 Jul 7;52(13):3817-36. doi: 10.1088/0031-9155/52/13/011. Epub 2007 May 31. Phys Med Biol. 2007. PMID: 17664579
-
Comparison of the 3D-conformal, helical tomotherapy and multileaf collimators-based intensity modulated radiotherapy modalities using radiobiological measures.J BUON. 2008 Jan-Mar;13(1):75-86. J BUON. 2008. PMID: 18404791
-
Comparison of the helical tomotherapy against the multileaf collimator-based intensity-modulated radiotherapy and 3D conformal radiation modalities in lung cancer radiotherapy.Br J Radiol. 2011 Feb;84(998):161-72. doi: 10.1259/bjr/89275085. Epub 2010 Sep 21. Br J Radiol. 2011. PMID: 20858664 Free PMC article.
-
Clinical implementation of adaptive helical tomotherapy: a unique approach to image-guided intensity modulated radiotherapy.Technol Cancer Res Treat. 2006 Oct;5(5):465-79. doi: 10.1177/153303460600500503. Technol Cancer Res Treat. 2006. PMID: 16981789 Review.
-
Tomotherapy and other innovative IMRT delivery systems.Semin Radiat Oncol. 2006 Oct;16(4):199-208. doi: 10.1016/j.semradonc.2006.04.002. Semin Radiat Oncol. 2006. PMID: 17010902 Review.
Cited by
-
Fractionated radiotherapy for spinal tumors: A literature review regarding spinal glioma, ependymoma, and meningioma.Neurooncol Adv. 2024 Feb 13;6(Suppl 3):iii101-iii109. doi: 10.1093/noajnl/vdad158. eCollection 2024 Oct. Neurooncol Adv. 2024. PMID: 39430392 Free PMC article. Review.
-
Clinical effect of multileaf collimator width on the incidence of late rectal bleeding after high-dose intensity-modulated radiotherapy for localized prostate carcinoma.Int J Clin Oncol. 2016 Feb;21(1):156-61. doi: 10.1007/s10147-015-0873-9. Epub 2015 Jul 12. Int J Clin Oncol. 2016. PMID: 26164689
-
A graphic user interface toolkit for specification, report and comparison of dose-response relations and treatment plans using the biologically effective uniform dose.Comput Methods Programs Biomed. 2010 Oct;100(1):69-78. doi: 10.1016/j.cmpb.2010.02.003. Epub 2010 Mar 24. Comput Methods Programs Biomed. 2010. PMID: 20338661 Free PMC article.
-
Comparing conformal, arc radiotherapy and helical tomotherapy in craniospinal irradiation planning.J Appl Clin Med Phys. 2014 Sep 8;15(5):4724. doi: 10.1120/jacmp.v15i5.4724. J Appl Clin Med Phys. 2014. PMID: 25207562 Free PMC article.
-
A novel inverse optimization based three-dimensional conformal radiotherapy technique in craniospinal irradiation.Phys Eng Sci Med. 2021 Mar;44(1):265-275. doi: 10.1007/s13246-021-00976-6. Epub 2021 Feb 8. Phys Eng Sci Med. 2021. PMID: 33559040
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous