Fine-needle cytology in the monitoring of human renal allograft progress
- PMID: 1916914
- DOI: 10.1016/0165-2478(91)90217-x
Fine-needle cytology in the monitoring of human renal allograft progress
Abstract
The differential diagnosis of early post-transplant renal dysfunction is complex. Clinical evaluation alone is often inaccurate and it is usually necessary to have recourse to additional investigation. Imaging methods, biochemistry and needle-core biopsy have all proved invaluable in this way, but for making consecutive evaluations of renal allografts, fine-needle aspiration cytology has now emerged as a safe, rapid and reliable addition. Indeed, with a such a negligible incidence of complications, aspirates may be taken on a regular basis with the information obtained not only helping in routine diagnosis but also providing a useful research insight into the dynamic nature of the rejection process. The technique has evolved mainly over the past two decades, initially being based on traditional, semi-quantitative, morphometric cytology. However, monoclonal antibody technology and immunocytochemistry have been developing over the same time period and much use has been made of such procedures as immunofluorescence, immunoperoxidase, immunogold-silver and immunoalkaline phosphatase in further, more subtle analyses of aspirated cell populations. Renal aspiration cytology has become an established technology which is now being adapted to the study of liver, pancreas and even lung allografts.
Similar articles
-
Increased accuracy of renal allograft rejection diagnosis using combined perforin, granzyme B, and Fas ligand fine-needle aspiration immunocytology.Transplantation. 2000 Jun 27;69(12):2547-53. doi: 10.1097/00007890-200006270-00013. Transplantation. 2000. PMID: 10910275
-
A prospective, randomized, blind comparison of three biopsy techniques in the management of patients after renal transplantation.Transplantation. 1992 Jun;53(6):1226-32. doi: 10.1097/00007890-199206000-00011. Transplantation. 1992. PMID: 1376503 Clinical Trial.
-
Fine needle aspiration biopsy in monitoring human renal transplant.Indian J Pathol Microbiol. 1995 Oct;38(4):393-7. Indian J Pathol Microbiol. 1995. PMID: 9726150
-
Fine needle aspiration biopsy and cytology in renal transplantation.Curr Opin Nephrol Hypertens. 2000 Nov;9(6):689-94. doi: 10.1097/00041552-200011000-00016. Curr Opin Nephrol Hypertens. 2000. PMID: 11128433 Review.
-
Fine-needle aspiration biopsy in the monitoring of liver allografts.Transpl Int. 1991 Apr;4(1):54-61. doi: 10.1007/BF00335517. Transpl Int. 1991. PMID: 2059301 Review.
Cited by
-
Towards minimally-invasive, quantitative assessment of chronic kidney disease using optical spectroscopy.Sci Rep. 2019 May 9;9(1):7168. doi: 10.1038/s41598-019-43684-8. Sci Rep. 2019. PMID: 31073168 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous