Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Feb;25(2):192-9.
doi: 10.1016/j.arthro.2008.09.010. Epub 2008 Nov 17.

Cyclic load and failure behavior of arthroscopic knots and high strength sutures

Affiliations
Comparative Study

Cyclic load and failure behavior of arthroscopic knots and high strength sutures

F Alan Barber et al. Arthroscopy. 2009 Feb.

Abstract

Purpose: To compare the biomechanical performance of several different sutures by evaluating knot security and load to failure strength using different arthroscopic knots.

Methods: Eight different No. 2 sutures (Ethibond [Ethicon, Somerville, NJ], FiberWire [Arthrex, Naples, FL], Orthocord [DePuy-Mitek, Norwood, MA], Hi-Fi [ConMed Linvatec, Largo, FL], Ultrabraid [Smith & Nephew, Andover, MA], ForceFiber [Stryker Endoscopy, San Jose, CA], MagnumWire [ArthroCare, Sunnyvale, CA], and MaxBraid PE [Arthrotek, Warsaw, IN]) were tied arthroscopically into standardized loops using 6 different knots (Weston, Tennessee slider, Duncan, SMC, Revo, and San Diego knot) 10 times each. The suture loops were pretensioned to 10N, cycled between 10N and 45N for 1,000 cycles, and loaded to failure. The failure load for each suture, each knot, and slippage trend during cyclic loading was recorded.

Results: The Revo and SMC knots (group A) were stronger than the Tennessee and San Diego knots (group B), which were stronger than the Weston knot, which was stronger than the Duncan loop (P < .05). This pattern also coincided with the loads at which these knots slipped. Evaluating the sutures showed that Ethibond had lower failure loads than all other sutures and FiberWire showed statistically higher loads (P < .05). Duncan loops (97.5%) and Weston knots (86.3%) slipped more than other knots (P < .001), while the SMC and Revo knots slipped least. Ethibond sutures were least likely to slip.

Conclusions: The Duncan loop and Weston knot were more likely to slip than all other knots, and caution should be exercised when tying them with high-strength sutures. The Revo, Tennessee slider, San Diego, and SMC knots were least likely to slip (P < .001).

Clinical relevance: While stronger than braided polyester sutures, newer sutures containing ultra-high molecular weight polyethylene have a greater tendency to slip. Backing up knots with 4 reversed half hitches with switched posts does not guarantee knot security.