Impact of blood cultures drawn by phlebotomy on contamination rates and health care costs in a hospital emergency department
- PMID: 19171686
- PMCID: PMC2668314
- DOI: 10.1128/JCM.02162-08
Impact of blood cultures drawn by phlebotomy on contamination rates and health care costs in a hospital emergency department
Abstract
We conducted a prospective comparison of blood culture contamination rates associated with dedicated phlebotomists and nonphlebotomy staff in the emergency department (ED) at Parkland Memorial Hospital in Dallas, TX. In addition, hospital charges and lengths of stay were determined for patients with negative, false-positive, and true-positive blood culture results. A total of 5,432 blood culture collections from two ED areas, the western wing of the ED (ED west) and the nonwestern wing of the ED (ED nonwest), were evaluated over a 13-month period. Phlebotomists drew 2,012 (55%) of the blood cultures in ED west while nonphlebotomy staff drew 1,650 (45%) in ED west and 1,770 (100%) in ED nonwest. The contamination rates of blood cultures collected by phlebotomists were significantly lower than those collected by nonphlebotomists in ED west (62/2,012 [3.1%] versus 122/1,650 [7.4%]; P < 0.001). Similar results were observed when rates between phlebotomists in ED west and nonphlebotomy staff in ED nonwest were compared (62/2,012 [3.1%] versus 100/1,770 [5.6%]; P < 0.001). Comparison of median patient charges between negative and false-positive episodes ($18,752 versus $27,472) showed $8,720 in additional charges per contamination event while the median length of stay increased marginally from 4 to 5 days. By utilizing phlebotomists to collect blood cultures in the ED, contamination rates were lowered to recommended levels, with projected reductions in patient charges of approximately $4.1 million per year.
References
-
- Bates, D. W., L. Goldman, and T. H. Lee. 1991. Contaminant blood cultures and resource utilization: the true consequences of false-positive results. JAMA 265365-369. - PubMed
-
- Bates, D. W., and T. H. Lee. 1992. Rapid classification of positive blood cultures: prospective validation of a multivariate algorithm. JAMA 2671962-1966. - PubMed
-
- Bekeris, L. G., J. A. Tworek, M. K. Walsh, and P. N. Valenstein. 2005. Trends in blood culture contamination: a College of American Pathologists Q-Tracks study of 356 institutions. Arch. Pathol. Lab. Med. 1291222-1225. - PubMed
-
- Cockerill, F. R., III, J. W. Wilson, E. A. Vetter, K. M. Goodman, C. A. Torgerson, W. S. Harmsen, C. D. Schleck, D. M. Ilstrup, J. A. Washington II, and W. R. Wilson. 2004. Optimal testing parameters for blood culture. Clin. Infect. Dis. 381724-1730. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Medical