Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009;88(3):325-31.
doi: 10.1080/00016340902730417.

Can ultrasound measurements replace digitally assessed elements of the Bishop score?

Affiliations
Free article

Can ultrasound measurements replace digitally assessed elements of the Bishop score?

Torbjørn M Eggebø et al. Acta Obstet Gynecol Scand. 2009.
Free article

Abstract

Objective: To compare elements of the Bishop score and corresponding sonographic measurements before induction of labor, and assess how predictive factors can be used in a clinical setting.

Design: Prospective comparative clinical study.

Setting: Secondary referral center, university hospital.

Population: A total of 275 women scheduled for induction of labor.

Methods: Fetal head descent to the perineum was assessed with transperineal ultrasound. Cervical length, posterior angle, and dilatation were evaluated with transvaginal ultrasound followed by Bishop score without knowledge of the ultrasound measurements.

Results: Univariable regression analyses of successful induction were significant for digital assessment of cervical dilatation, ultrasound measured fetal head-perineum distance < or =40 mm, ultrasound measured cervical length < or =25 mm, and ultrasound measured posterior cervical angle >90 degrees. After adjusting for maternal factors in a multivariable model, estimates were significant for previous vaginal birth (OR 5.3; 95% CI 2.1-13.9, p<0.01), but borderline for maternal height (OR 1.1; 95% CI 1.0-1.2, p=0.01) and ultrasound measured posterior cervical angle >90 degrees (OR 2.6; 95% CI 1.1-6.1, p=0.03). A scoring model combining ultrasound measured fetal head-perineum distance, cervical length, cervical posterior angle and digitally assessed cervical dilatation, discriminated successful and failed induction at 71% (95% CI 61-80%, p<0.01) area under the receiver-operating characteristics curve.

Conclusion: Digital assessment of fetal head descent, cervical length and position can possibly be replaced with ultrasound measurements. Dilatation is best evaluated with digital assessment. Combination of these four factors can predict success of labor induction.

PubMed Disclaimer