Instrumentation of the loss-of-resistance technique for epidural needle insertion
- PMID: 19174346
- DOI: 10.1109/TBME.2008.2011475
Instrumentation of the loss-of-resistance technique for epidural needle insertion
Abstract
Epidural anesthesia is the most common form of anesthesia in obstetrics. The loss-of-resistance to saline injection is used to confirm when the needle tip enters the epidural space. This procedure is highly dependent on skill and expertise, so it is useful to quantify the tissue resistance during insertion. Sensors are used to measure the force and displacement of the plunger of the syringe and the pressure at the needle tip. A model is also developed to estimate the pressure from the force and displacement. Tests are first performed on porcine tissue to compare the continuous-pressure and intermittent-pressure versions of the technique and to compare the paramedian and midline needle approaches. The accuracy of the pressure model is 12% of peak pressure for the continuous technique and 20% for the intermittent technique. Significant differences in injection flow rate were also found for the muscle, interspinous ligament, and ligamentum flavum encountered in the two approaches. A small clinical study on human subjects was performed and again significant differences were found in flow rate for different tissues. These quantitative results improve the understanding of small differences in feel that have been previously known qualitatively and may help in the development of simulators.
Similar articles
-
Towards a realistic in vitro experience of epidural Tuohy needle insertion.Proc Inst Mech Eng H. 2013 Jul;227(7):767-77. doi: 10.1177/0954411913483428. Epub 2013 Apr 4. Proc Inst Mech Eng H. 2013. PMID: 23636758
-
The BiP Test: a modified loss of resistance technique for confirming epidural needle placement.Pain Physician. 2006 Oct;9(4):323-5. Pain Physician. 2006. PMID: 17066116 Review.
-
A 'membrane in syringe' technique that allows identification of the epidural space with saline while avoids injection of air into the epidural space.Acta Anaesthesiol Sin. 2002 Jun;40(2):55-60. Acta Anaesthesiol Sin. 2002. PMID: 12194391 Clinical Trial.
-
Technique of fiber optics used to localize epidural space in piglets.Opt Express. 2010 May 24;18(11):11138-47. doi: 10.1364/OE.18.011138. Opt Express. 2010. PMID: 20588973
-
Epidural space identification: a meta-analysis of complications after air versus liquid as the medium for loss of resistance.Anesth Analg. 2009 Dec;109(6):2012-21. doi: 10.1213/ANE.0b013e3181bc113a. Anesth Analg. 2009. PMID: 19923534 Review.
Cited by
-
Epidural loss-of-resistance biomechanics: an open pilot cadaver study.Local Reg Anesth. 2010;3:101-7. doi: 10.2147/LRA.S11932. Epub 2010 Sep 6. Local Reg Anesth. 2010. PMID: 22915876 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources