Scheimpflug photography keratometry readings for routine intraocular lens power calculation
- PMID: 19185251
- DOI: 10.1016/j.jcrs.2008.10.041
Scheimpflug photography keratometry readings for routine intraocular lens power calculation
Abstract
Purpose: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery.
Setting: Private clinical ophthalmology practice, Lynwood, California, USA.
Methods: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas.
Results: The mean automated K value was 43.49 diopters (D)+/-1.75 (SD) and the mean simulated K value, 43.49+/-2.00 D (P> .1). The mean equivalent K value was 43.78+/-1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P> .1). The mean true net K was 42.31+/-2.13 D, which was 1.18 D lower than the automated K and simulated K values (P= .015). The IOL prediction mean absolute error was 0.41+/-0.27 D using the automated K method, 0.50+/-0.36 D using the simulated K method (difference 0.09 D) (P> .1), and 0.65+/-0.35 D using the equivalent K method (difference 0.24 D) (P< .01).
Conclusion: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
Similar articles
-
Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.J Cataract Refract Surg. 2009 Jul;35(7):1198-203. doi: 10.1016/j.jcrs.2009.02.030. J Cataract Refract Surg. 2009. PMID: 19545808
-
Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes.J Cataract Refract Surg. 2012 May;38(5):787-92. doi: 10.1016/j.jcrs.2011.11.037. Epub 2012 Mar 2. J Cataract Refract Surg. 2012. PMID: 22386277
-
Automated keratometry in routine cataract surgery: comparison of Scheimpflug and conventional values.J Cataract Refract Surg. 2011 Feb;37(2):295-301. doi: 10.1016/j.jcrs.2010.08.050. J Cataract Refract Surg. 2011. PMID: 21241912
-
Calculation of intraocular lens power: a review.Acta Ophthalmol Scand. 2007 Aug;85(5):472-85. doi: 10.1111/j.1600-0420.2007.00879.x. Epub 2007 Apr 2. Acta Ophthalmol Scand. 2007. PMID: 17403024 Review.
-
Biometry and intraocular lens power calculation.Curr Opin Ophthalmol. 2008 Jan;19(1):13-7. doi: 10.1097/ICU.0b013e3282f1c5ad. Curr Opin Ophthalmol. 2008. PMID: 18090891 Review.
Cited by
-
Comparison of Holladay equivalent keratometry readings and anterior corneal surface keratometry measurements in keratoconus.Int Ophthalmol. 2019 Jul;39(7):1501-1509. doi: 10.1007/s10792-018-0967-2. Epub 2018 Jun 22. Int Ophthalmol. 2019. PMID: 29934929
-
Comparison of Anterior Segment Measurements with Scheimpflug/Placido Photography-Based Topography System and IOLMaster Partial Coherence Interferometry in Patients with Cataracts.J Ophthalmol. 2014;2014:540760. doi: 10.1155/2014/540760. Epub 2014 Oct 23. J Ophthalmol. 2014. PMID: 25400939 Free PMC article.
-
Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.Middle East Afr J Ophthalmol. 2016 Jan-Mar;23(1):122-8. doi: 10.4103/0974-9233.171755. Middle East Afr J Ophthalmol. 2016. PMID: 26957851 Free PMC article.
-
Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery.Graefes Arch Clin Exp Ophthalmol. 2019 Dec;257(12):2677-2682. doi: 10.1007/s00417-019-04443-7. Epub 2019 Sep 5. Graefes Arch Clin Exp Ophthalmol. 2019. PMID: 31486917
-
Agreement between Pentacam and handheld Auto-Refractor/Keratometer for keratometry measurement.J Optom. 2019 Oct-Dec;12(4):232-239. doi: 10.1016/j.optom.2019.06.001. Epub 2019 Jul 10. J Optom. 2019. PMID: 31300242 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources