Abstract
Background: Late incomplete stent apposition (ISA) may occur after drug-eluting stent implantation, affecting long-term clinical outcomes. This study aimed to evaluate the impact of clinical presentations of coronary artery disease on late ISA after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) by means of three-dimensional volumetric intravascular ultrasound (IVUS) analyses.
Methods: One hundred and thirty-seven patients with coronary artery disease received SES implantation during PCI and had repeat angiography with IVUS examination. All patients were followed up one year after the procedure.
Results: In overall 219 treated lesions (137 patients), late ISA was identified in 25 lesions (16 patients). Clinical diagnosis of acute coronary syndrome (ACS) and use of long stents were more common in patients with than in those without late ISA. Patients with late ISA had greater external elastic membrane (EEM) area in stented segment ((15.34 +/- 5.44) vs (13.83 +/- 4.51) mm(2), P = 0.026), stented-to-reference segment EEM area ratio (1.13 +/- 0.22 vs 1.02 +/- 0.18, P < 0.001), and plaque and media area ((8.43 +/- 3.93) vs (7.01 +/- 2.93) mm(2), P = 0.002) than in those without late ISA. Multivariate Logistic regression analysis showed that clinical diagnosis of ACS and use of long stents were independent risk factors for late ISA (OR 6.477, 95% CI 2.297 - 18.263, P < 0.001; OR 3.680, 95% CI 1.181 - 11.469, P = 0.025; respectively). During one-year follow-up after IVUS examination, the rate of very late stent thrombosis tended to be higher in patients with than in those without late ISA (18.7% vs 3.3%, P = 0.051).
Conclusions: The occurrence of late ISA after SES implantation may be related to clinical status, use of long stents, and marked positive vessel remodeling. Late ISA tended to increase the rate of very late stent thrombosis during follow-up, highlighting the importance of long-term dual antiplatelet therapy for these patients.
Similar articles
-
[Association between late incomplete stent apposition after sirolimus eluting stent implantation and clinical outcomes in patients with acute coronary syndrome].Zhonghua Xin Xue Guan Bing Za Zhi. 2009 Jan;37(1):30-4. Zhonghua Xin Xue Guan Bing Za Zhi. 2009. PMID: 19671348 Chinese.
-
Impact of angiographic and intravascular ultrasound features on clinical outcome after sirolimus-eluting stent implantation for de-novo lesions in nondiabetic and type 2 diabetic patients.Coron Artery Dis. 2010 May;21(3):175-81. doi: 10.1097/MCA.0b013e32833811fe. Coron Artery Dis. 2010. PMID: 20305549
-
Risk of late-acquired incomplete stent apposition after drug-eluting stent versus bare-metal stent. A meta-analysis from 12 randomized trials.J Invasive Cardiol. 2008 Aug;20(8):417-22. J Invasive Cardiol. 2008. PMID: 18688067
-
Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings.J Am Coll Cardiol. 2006 May 16;47(10):2108-11. doi: 10.1016/j.jacc.2005.11.092. Epub 2006 Apr 4. J Am Coll Cardiol. 2006. PMID: 16697331 Review.
-
Very late thrombosis after drug-eluting stents.Catheter Cardiovasc Interv. 2006 Jul;68(1):83-8. doi: 10.1002/ccd.20692. Catheter Cardiovasc Interv. 2006. PMID: 16763989 Review.
Cited by
-
Optimizing the duration of dual antiplatelet therapy after implantation of drug-eluting coronary stents.Chin Med J (Engl). 2015 Mar 20;128(6):711-3. doi: 10.4103/0366-6999.152446. Chin Med J (Engl). 2015. PMID: 25758260 Free PMC article. No abstract available.
-
Extensive late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.Korean Circ J. 2010 Jan;40(1):50-3. doi: 10.4070/kcj.2010.40.1.50. Epub 2010 Jan 27. Korean Circ J. 2010. PMID: 20111654 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous