. 2009 Jun;37(5):381-386.
doi: 10.1016/j.ajic.2008.09.021. Epub 2009 Feb 1.

Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage

Affiliations

Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage

Dennis J Viscusi et al. Am J Infect Control. 2009 Jun.

Abstract

Background: Organizations are stockpiling respirators to prepare for an influenza pandemic. To understand better the effects of prolonged storage, this investigation evaluated the filtration efficiency of 21 different models of National Institute for Occupational Safety and Health (NIOSH)-certified disposable N95 filtering face piece respirators. These respirators had been stored in their original packaging for a period of at least 6 years in research laboratories and dry warehouse facilities, ranging in temperature between 15 degrees C and 32 degrees C and relative humidity between 20% and 80%.

Methods: Filter penetration was measured using an abbreviated version of the NIOSH respirator certification test incorporating a polydisperse sodium chloride aerosol at 85 L/min.

Results: Of the 21 respirator models tested, 19 models had both average penetration results of less than 5%. Mean initial penetration values ranged from 0.39% to 5.83%, whereas mean maximum penetration values ranged from 0.95% to 5.83%. There did not appear to be any correlation between the length of storage and failure to pass the filtration test.

Conclusion: Results indicate that most N95 filtering face piece respirators stored for up to 10 years at warehouse conditions will likely have expected levels of filtration performance and that the degree of filtration efficiency degradation is likely model specific.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Institute of Medicine (US) The Institute; Washington: 2006. Reusability of facemasks during an influenza pandemic.
    1. Rubinson L., Nuzzo J.B., Talmor D.S. Augmentation of hospital critical care capacity after bioterrorist attacks or epidemics: recommendations of the Working Group on Emergency Mass Critical Care. Crit Care Med. 2005;33(Suppl):E2393. - PubMed
    1. Schmit J. Disposable respirator demand on rise. USA TODAY 2006 August 17. Available at: http://www.usatoday.com/money/industries/health/2006-08-17-n95-masks-usa.... Accessed May 14, 2008.
    1. Roberge R. Effect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden. J Pub Health Manage. 2008;14:E19–E26. - PubMed
    1. Hinds W.C. 2nd ed. Wiley; New York: 1998. Aerosol technology: properties, behavior, and measurements of airborne particles. p. 196.

Publication types