Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Jun;40(4):455-62.
doi: 10.1016/j.micron.2008.12.008. Epub 2008 Dec 27.

Second harmonic generation from thick leaves using the two-photon laser scanning microscope

Affiliations

Second harmonic generation from thick leaves using the two-photon laser scanning microscope

Ali Hussain Reshak. Micron. 2009 Jun.

Abstract

A laser-scanning microscope using second harmonic generation (SHG) as a probe is shown to produce high-resolution images of duckweed Lemna minuta leaves. These leaves are multi-cell layer thick. Second harmonic light is generated by a tightly focused short pulse laser beam and is collected by two objectives yielding forward and backward second harmonic digital images. This measurement shows that the signal of the second harmonic imaging in the forward and backward directions depends on the thickness of the chloroplast and that the forward-SH image was brighter than the backward-SH image. The image intensity also depended on the orientation of the chloroplast in relation to the illuminating polarization direction. Their light-induced re-orientation which was affected by the intensity of the illumination could be observed during the experiments. The novelty of this work is to establish new compact technique in which one can use the SH imaging to investigate the true architecture of the sensitive samples, the unknown samples and the samples which is not producing auto-fluorescence. Moreover, investigation of new or unknown samples needs a long time for looking at details of the sample. Thereby the sample will be exposed for long time to the laser radiation that will cause photobleaching and photodamage. Since the SHG does not undergo photobleaching and photodamage this will be the promising technique for investigating the sensitive and new unknown samples. Then one can move to acquire fluorescence images after complete investigation of the true architecture of the sample. The other advantage of SHG is that it has the ability to image highly ordered structural proteins without any exogenous labels. The SHG is an intrinsic and a coherent process. Imaging of intrinsic compounds avoids the complications of slicing and labeling, and samples can be investigated under physiological conditions.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources